29KX-TG6421FXS/KX-TG6421FXT/KX-TGA641FXS/KX-TGA641FXTFrequently Used Items (Base Unit)ex.)Note:(*1) Refer to Registering a Handset to a Base Unit (P.21).(*2) When you enter the address or New Data, please refer to the table below.(*3)Items Address Default Data New Data RemarksC-ID (FSK) sensitivity 04 B6 00 01 (6 dB up) 02 (12 dB up) When hex changes from “00” to “01” or “02”,gain increases by 6 dB or 12 dB.C-ID (DTMF) sensitivity 04 C4 50 60 (6 dB up) 70 (12 dB up) When hex changes from “50” to “60” or “70”,gain increases by 6 dB or 12 dB.SMS (FSK) receiving sensitiv-ity04 B6 00 01 (6 dB up) 02 (12 dB up) When hex changes from “00” to “01” or “02”,gain increases by 6 dB or 12 dB.SMS (FSK) sending level 04 D0/04 CF 13/3B 19/20 (6 dBup)32/40 (12 dBup)When hex changes from “00 0B” to “00 16” or“00 2C”, gain increases by 6 dB or 12 dB.Frequency 00 02/00 01 02/70 - - Use these items in a READ-ONLY mode toconfirm the contents. Careless rewriting maycause serious damage to the computer system.ID 00 10~00 14 Given value - -Bell length 01 F7 32 (5sec) (*3) 1E (3 sec) 14 (2 sec) This is time until bell stops ringing.(Unit: 100 ms)PULSE Dial speed(10PPS -> 20PPS)03 9F 2D (40msec)(*3)13 (20msec) - This is pulse make time. (Unit:1ms)03 A0 37 (60msec)(*3)1F (30msec) - This is pulse break time. (Unit:1ms)01 E4 57 (870msec)(*3)2C (440msec) - This is inter-digit time in pulse mode.(Unit:10ms)Items Address Default Data New Data RemarksSMS MailBox1 Password 3F BC/3F BD Given value 00/00 When New Data is input, the password ofMailBox1 becomes “0000”.SMS MailBox2 Password 3F BE/3F BF Given value 00/00 When New Data is input, the password ofMailBox2 becomes “0000”.SMS MailBox3 Password 3F C0/3F C1 Given value 00/00 When New Data is input, the password ofMailBox3 becomes “0000”.SMS MailBox4 Password 3F C2/3F C3 Given value 00/00 When New Data is input, the password ofMailBox4 becomes “0000”.SMS MailBox5 Password 3F C4/3F C5 Given value 00/00 When New Data is input, the password ofMailBox5 becomes “0000”.SMS MailBox6 Password 3F C6/3F C7 Given value 00/00 When New Data is input, the password ofMailBox6 becomes “0000”.Desired Number (hex) Input Keys Desired Number (hex) Input Keys0 0 A [R] + 01 1 B [R] + 1. . C [R] + 2. . D [R] + 3. . E [R] + 49 9 F [R] + 5Bell length 32 (hex) = 50 (dec) → 50 × 100 msec = 5000 msec (5 sec)PULSE Dial speed(10PPS -> 20PPS)2D (hex) = 45 (dec) → (45 - 5) × 1 msec = 40 msec37 (hex) = 55 (dec) → (55 + 5) × 1 msec = 60 msec57 (hex) = 87 (dec) → 87 × 10 msec = 870 msec