37KX-TG7100FXS/KX-TG7100FXT/KX-TG7102FXS/KX-TGA711FXS/KX-TGA711FXT9.3. Troubleshooting by Symptom (Handset)If your unit has below symptoms, follow the instructions in remedy column. Remedies depend on whether you have DECT tester(*1) or not.Note:(*1) A general repair is possible even if you don’t have the DECT tester because it is for confirming the levels, such as Acousticlevel in detail.(*2) Refer to Check Point (Handset) (P.37)9.3.1. Check Point (Handset)Please follow the items below when BBIC or EEPROM is replaced.Note:After the measuring, suck up the solder of TP.*: PC Setting (P.50) is required beforehand.The connections of adjustment equipments are as shown in Adjustment Standard (Handset) (P.52).Items CheckPointProcedure Check orReplace Parts(A)* 1.8 V Supply Adjustment VDD1 1. Confirm that the voltage between test point VDD1 and GND is 1.8 V ± 0.02 V.2. Execute the command “bandgap”, then check the current value.3. Adjust the 1.8V voltage of VDD1 executing command “bandgap XX“(XX is thevalue).IC1, Q2, C10(B) DC/DC Supply Confir-mationVDD3 1. Confirm that the voltage between test point VDD3 and GND is 3.3 V ± 0.3 V(Backlight is ON).IC1, F1, C1,C2, C3, R1,Q1, D1, L1(C) 2.5 V Supply Confirma-tionVDD2 1. Confirm that the voltage between test point VDD2 and GND is 2.5 V ± 0.1 V. IC1, Q3, C5(D)* BBIC Confirmation - 1. BBIC Confirmation (Execute the command “getchk”).2. Confirm the returned checksum value.Connection of checksum value and program number is shown below.IC1, X1, C6,C7, R19(E)* EEP-ROM Confirmation - 1. EEP-ROM Confirmation (Execute the command “ChkTGA711XXrevYY”).XX: country codeYY: revision number2. Confirm the returned checksum value.Note:“XX”, “YY”, and “checksum” vary depending on the country version. You can findthem in the batch file, PQZZ- mentioned in JIG and PC (P.46).IC1, IC3, R40,R41, R42,Q10, Q11,R43, R44,C37(F) Charge Control Check &Charge Current MonitorCheck- 1. Apply 3.5 V between J3(+) and J4(-) with DC power supply and set current limitto 250 mA.2. Confirm that the current limit LED of DC power supply is ON/OFF.3. Decrease current limit of DC power supply to 100mA.4. Confirm that the current limit LED of DC power supply is stable. (Current limiteris ON.)(If charge control cannot be confirmed by this procedure, please use battery to hand-set power supply and try again.)IC1, Q4, Q5,Q9, D6, D7,D8, L4,L5, R5, R6,R7, R8, F1