42KX-TG8011MES/KX-TGA800MES(M)* Frequency Drift Confir-mation-ANTI_TPFollow steps 1 to 6 of (J).7.Confirm that the frequency drift is < ± 20 kHz/ms.IC7, L7, C117,C118, C124,C125, R106,R109,DA1,R802~R807,C837, C826,C822, C820,C832, C833,C123, C74, Q9,C617~C621,C65, IC801,D801, D802,C801~C804,C808~C814,L802~L804,C819, C834,C825(N)* Sensitivity ReceiverConfirmation-ANTI_TPFollow steps 1 to 6 of (J).7.Set DECT tester power to -90 dBm.8.Confirm that the BER is < 1000 ppm.IC7, L7, C117,C118, C124,C125, R106,R109,DA1,R802~R807,C837, C826,C822, C820,C832, C833,C123, C74, Q9,C617~C621,C65, IC801,D801, D802,C801~C804,C808~C814,L802~L804,C819, C834,C825(O)* Timing Confirmation -ANTI_TPFollow steps 1 to 6 of (J).7.Confirm that the Timing accuracy is• ± 5.0 ppm (When adjust the frequency of CLK in item (G)).• ± 15 ppm (When do not adjust the frequency of CLK in item (A)).IC7, L7, C117,C118, C124,C125, R106,R109,DA1,R802~R807,C837, C826,C822, C820,C832, C833,C123, C74, Q9,C617~C621,C65, IC801,D801, D802,C801~C804,C808~C814,L802~L804,C819, C834,C825(P)* Power RAMP Confirma-tion- Follow steps 1 to 6 of (J).7.Confirm that Power RAMP is matching.IC7, L7, C117,C118, C124,C125, R106,R109,DA1,R802~R807,C837, C826,C822, C820,C832, C833,C123, C74, Q9,C617~C621,C65, IC801,D801, D802,C801~C804,C808~C814,L802~L804,C819, C834,C825Items CheckPointProcedure Check orReplace Parts