Panasonic LA-A1 Instruction Manual
Also see for LA-A1: Instruction manual
INSTRUCTION MANUALCollimated Beam Sensor LA-A1 / LA-A1PCMJE-LAA1 (06)No.0042-36VThank you very much for purchasing Panasonic products. Read this Instruction Man-ual carefully and thoroughly for the correct and optimum use of this product. Kindlykeep this manual in a convenient place for quick reference.WARNING Never use this product as a device for personnel protection. In case of using devices for personnel protection, use products whichmeet laws and standards, such as OSHA, ANSI or IEC etc., for personnelprotection applicable in each region or country.1 FUNCTION DESCRIPTIONPOWERSTB SPANSHIFTESHIGHLOWLA-A112345671089Description Function1 Power indicator (Green㧕 Lights up when the power is supplied.2 Stability indicators(Green×3) Light up in three steps in proportion to theintensity of received beam.3 HIGH operation indicator (Orange) Lights up when HIGH output is ON.4 External synchronizationindicator (Green) Lights up when the external synchronizationinput is LOW.(Active-LOW)5 External synchronizationselection switchSelects between gate trigger( ) / or edgetrigger( )6 LOW operation indicator(Orange) Lights up when LOW output is ON.7 Span adjuster 15-turn adjuster sets the span for the analogoutput voltage.8 Shift adjuster 15-turn adjuster sets the offset for the analogoutput voltage. It calibrates the outputvoltage at zero input.9 HIGH level adjuster 15-turn adjuster sets the HIGH outputthreshold level.(Over-dark level).10 LOW level adjuster 15-turn adjuster sets the LOW outputthreshold level.(Under-dark level).2 MOUNTING Mounting on DIN rail1. Make sure the mounting stopper islatched inside. Hook the front sideof the controller on the 35mm widthDIN rail at the bottom.2. Snap the controller down on the35mm width DIN rail.* -driver into the mounting stopperand pull out.Stopper1 35mm widthDIN rail2Flathead screwdriverStopper Mounting with screwsUse two M4 screws that are com-mercially available. The tighteningtorque should be 1.2N㨯m or less.M4 pan headscrewsPlease arrangeseparately.3 CONNECTION Wiring diagramReceiver EmitterCableColor codeLower terminal blockfor the emitterUpper terminal blockfor the receiverBrownWhiteBlueShieldBrownBlueShieldSTB SPANSHIFT123456789POWERLA-A16789 2345Orange / VioletConnect color-coded wires in accordancewith the table below.The receiver wiresshould be connected on the upper terminalblock and the emitter wires on the lower ter-minal block.'OKVVGT 4GEGKXGTTerminalNo. Color code TerminalNo. Color code2 5JKGNF 6 5JKGNF3 Orange / Violet 7 9JKVG4 $NWG 8 $NWG5 $TQYP 9 $TQYPNote: Do not connect any wire to the terminal No.1 I/O circuit diagram㧨LA-A1 NPN 㧪100mA max.100mA max.75ǡ98765432Terminal No.Color code Color codesReceiverEmitter(Brown) +V(Gray) Analog output +(Pink) External synchronization input ES +(Pink / Blue) External synchronization input ES(Shield) Analog output(Blue) 0V0V (Blue)0V (Blue)SYNC.ShieldShieldMain circuit㧗㧙LoadLoad +*1Users' circuitAmplifier internalcircuitSensor headsNon-voltage contact orNPN open-collector transistorLow: 0 to 1V High: +V or Openor*1 I/O circuit diagram㧨LA-A1P PNP 㧪*1Note 1):㧨NPN㧪When ES + (pink) and ES - (pink / blue) are connected, both HIGH and LOWcomparative outputs are triggered in the mode selected by the external synchronizationselection switch.2):㧨PNP㧪When ES (pink/blue) and ES (pink) are connected, both HIGH andLOWcomparative outputs are triggered in the mode selected by the external synchronizationselection switch.3):To disable external synchronization, set the external synchronization selection switch on'Gate trigger' and short-circuit the external synchronization inputs (ES + and ES -). !" #" "$#& " ;<more and connect the shield wire of the along output to 0V (common input) of the device.5):Insulate all unused wires individually to avoid mis-contact.4 EXTERNAL SYNCHRONIZATION FUNCTION The external synchronization input controls the timing or the effectiveduration of the two comparative outputs. Either, edge, or, gate trigger isselectable.Gate trigger Edge triggerExternal synchronizationselection switchONOFFHighLowONOFFONOFFHighLowONOFFAprox40msSensing signalExternal synchronizationinputComparative outputs㧔HIGH,LOW㧕External synchronization input signal : LOW ... 0 to 1V, High ...+V or OpenNote: To disable external synchronization, set the external synchronization selection switch on 'Gate trigger' and short-circuit the external synchronization inputs (ES+ and ES -).5 ALIGNMENT Beam alignment of sensor heads Make sure that, at least, one stability indicator lights up when you supply LA-305 sensor heads. While aligning sensorheads, the more stability indicators light up, the more reliable detection can beobtained. If either sensor head moves out of position, do all adjustments, including beamalignment, from the beginning.Refer to the instruction manual of LA-305 for more details of beam alignment of sensor heads Calibrating analog output The analog voltage output relates to the span and the shift adjustments as in How to calibrate the output into 1 to 5V1. Block the whole beam to enter into thedarkest condition and set the output at1V with the shift adjuster.2. Allow the whole beam to be received toenter into the lightest condition and setthe output at 5V with the span adjuster.3. For more accurate calibration, repeat 1and 2.5V1VSpanadjustmentShiftadjustmentDarkestconditionLightestconditionIncidentbeamintensityAnalog output㧨Explanation㧪(e.g.) Wire detectionAWireCollimated beamBC Incident beam width = A + C Interrupted beam width = B Lightest condition: The entire beam is received. Darkest condition: The entire beam is blocked.Further use of shift adjuster If you want to change the output voltage value after the calibration, the shiftadjuster enables you to shift the analog voltage up or down within about ±0.5V.(e.g.) To shift the analog voltage from 2.51V to 3V with a certain amount of beam blockageޕCollimated beamSensing objectEmitterReceiver Darkest conditionSetting conditionLightest conditionPrevious1Vto2.51Vto5VSubsequent1.49Vto3Vto5.49V(Application) When two sensor heads are used for width measurement the shift adjuster caneliminate the need to move the sensor heads during set-up.Reference widthCollimatedbeamCollimatedbeamSensing objectEmitter ReceiverEmitter Receiver Up to now, the sensor heads have had to be locatedat the exact positions with respect to the referenceobject to measure at the criterion of 3V, center of 1to 5V. However, even a simulated center is easilyobtained by the shift adjustment, without anyrealignment.Note: To make the whole beam balanced between the lightestand darkest conditions, the sensor heads should be posi-tioned where the sensor generates 3V with the beam halfblocked. Adjusting HIGH & LOW output levels (Two independent outputs)HIGH output threshold level Block as much of the beam for which you wantthe HIGH output. Turn the HIGH adjuster to justbefore the point where the HIGH operation indi-cator lights up. The threshold level increases asthe adjuster is turned clockwise.LOW output threshold level Again, block as little of the beam for which youwant the LOW output. Turn the LOW adjuster tojust before the point where the LOW operationindicator lights up. The threshold level increasesas the adjuster is turned clockwise.$?!@ QYZQ[\] #^ _LOWoutputlevelHIGHoutputlevelONOFFONOFFDarkestconditionLightestconditionIncidentbeamintensityComparativeoutput (HIGH)Comparativeoutput (LOW)HighLow Analog voltage6 MAJOR SPECIFICATIONSDesignation ` ^ 㨯 Model No. LA-A1 LA-A1PApplicable sensor head LA305㧔Note)Supply voltage 12 to 24V DC±10% Ripple P-P 10% or lessCurrent consumption 120mA or less (including sensor heads)Comparative outputs(HIGH,LOW)NPN open-collector transistor PNP open-collector transistorMaximum sink current: 100mAApplied voltage: 30V DC or less(between comparative outputand 0V)Residual voltage: 1.5V or less(at 100mA sink cur-rent)0.5V or less(at 16mA sink cur-rent)Maximum sink current: 100mAApplied voltage: 30V DC or lessResidual voltage: 1.5V or less(at 100mA source cur-rent )0.5V or less(at 16mA source cur-rent)Response time 0.5ms or lessOutputoperationHIGH OUT: ON when the received beam level is equal or lower thanOver-dark levelLOW OUT: ON when the received beam level is equal or higher thanUnder-dark levelShort-circuitprotection IncorporatedAnalog outputAnalog voltageOutput voltage: 1V (Darkest) to 5V (Lightest)\" " !Slew rate 8V/ms or moreTemperaturecharacteristics 0.05%F.S./͠ or lessAmbient temperature 0 to +50͠ (No dew condensation), Storage: -20 to +70͠Ambient humidity 35 to 85% RH, Storage: 35 to 85% RHMaterial Enclosure: Heat-resistant ABS, Terminal cover: Heat-resistantABSFront cover: PolycarbonateCable 0.22mm2 (Shield wire:0.15mm 2 ) 7-core composite cabtyre, 2m longAccessory Adjusting screwdriver: 1 pc.Note: Refer to the instruction manual of LA-305 for more details.7 CAUTIONSMake sure to use the exclusive sensor head LA-305 & # _ This product has been developed / produced for industrial use only. Make sure that the power supply is off while wiring. Take care that wrong wiring will damage the sensor. Verify that the supply voltage variation is within the rating. If power is supplied from a commercial switching regulator, ensure that theframe ground (F.G.) terminal of the power supply is connected to an actualground. In case noise generating equipment (switching regulator, inverter motor,etc.) is used in the vicinity of this product, connect the frame ground (F.G.)terminal of the equipment to an actual ground. Do not run the wires together with high-voltage lines or power lines or putthem in the same raceway. This can cause malfunction due to induction. Extension up to total 50m, or less, is possible with 0.22mm 2 , or more,cable.Use a shielded cable for extension of the analog output cable. In case of using this product as a CE marking conformity product, cableextension of the power wire and I/O wire must be wthin 30m. ! "#the output until stabilized. Make sure that stress by forcible bend or pulling is not applied directly to thesensor cable joint. This sensor is suitable for indoor use only. Do not use this sensor in places having excessive vapor, dust, etc., or where itmay come in direct contact with water, or corrosive gas Take care that the sensor does not come in direct contact with water, oil,grease, organic solvents, such as, thinner etc., strong acid or alkaline. Make sure to mount the terminal cover8 INTENDED PRODUCTS FOR CE MARKING The models listed under “ 6 MAJOR SPECIFICATIONS” come withCE Marking. As for all other models, please contact us. Contact for CEPanasonic Marketing Europe GmbH Panasonic Testing CenterWinsbergring 15, 22525 Hamburg,GermanyPhone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com |
Related manuals for Panasonic LA-A1
Panasonic LA-511 Instruction Manual
Panasonic LM10 Instruction Manual
Panasonic LM10 Instruction Manual
Panasonic GP-A5S Instruction Manual
Panasonic HG-S Instruction Manual
Panasonic PX-21 Instruction Manual
Panasonic EQ-34 Instruction Manual
Panasonic GA-311 Instruction Manual
Panasonic EX-FC1 Instruction Manual
Panasonic EX-FC1 Instruction Manual
manualsdatabase
Your AI-powered manual search engine