76No. Name and descriptionY16Y17Y18Y19INTERLOCK 1 MONITOR: Interlock 1 monitoringINTERLOCK 1 MONITOR COM.: Interlock 1 monitoring commonINTERLOCK 2 MONITOR: Interlock 2 monitoringINTERLOCK 2 MONITOR COM.: Interlock 2 monitoring commonINTERLOCK 1 MONITOR (Y16 - Y17) monitors the contact status of INTERLOCK 1 (X16 - X17). INTERLOCK2 MONITOR (Y18 - Y19) monitors the contact status of INTERLOCK 2 (X18 - X19). For details, refer to “4-4-3Interlock terminal rating and I/O circuit” (P.87).State of INTERLOCK terminals Operation of INTERLOCK MONITOR terminalsX16 - X17: OPEN Y16 - Y17: CLOSEX16 - X17: CLOSE (Short-circuited) Y16 - Y17: OPENX18 - X19: OPEN Y18 - Y19: CLOSEX18 - X19: CLOSE (Short-circuited) Y18 - Y19: OPENInterlock monitor is switched open and closed with a delay of approx. 20ms with reference to each interlockinput as shown below.20ms 20msINTERLOCK(+) - INTERLOCK(-)(X16 - X17, X18 - X19)INTERLOCK MONITOR - INTERLOCK MONITOR COM.(Y16 - Y17, Y18 - Y19)CLOSEOPENCLOSEOPENY20 LASING OUT: Laser radiation outputOutput ON during laser radiation.In case the lasing time is shorter than the set one-shot output time, the lasing output remains ON until theone-shot output time ends. *1ンㄆㄇㄆㄓㄆㄏㄆ• Use PROCESSING END OUT (Y11) and PROCESSING FAIL OUT (Y12) for the confirmation of markingcompletion.*1 : Set the output time of the one-shot output on the system settings screen of Laser Marker NAVI smart. The settingrange is 2 to 510ms. The initial setting value is 40ms. One-shot output time has a small margin of error for the settingvalue.ME-LPGS-SM-8