9.2. SERVICE MENUWhen abnormal detection contents are confirmed a When I do the following operation automatic diagnosis cord isdisplayed. (Service mode)This function displays the following items in the Service Menu.· *1 ... Mechanism lock code recordThe current lock code, the last lock code and the lock code before last are displayed.· *2 ... Lens motor lock code recordThe current lock code, the last lock code and the lock code before last are displayed.Making the mode dial of This Machine a PC connection mode push [QUICK START] button and [JOYSTICK LEFT ] buttonand [PHOTO SHOT] button simultaneously for 3 seconds (with no SD Card inserted).The Service Menu will be displayed.NOTE:In the case that a tape or SD Card is included the above operation does not work.Self diagnosis cord contents are as followsDisplay position → Cord specificationDisplay contents(Self diagnosis cord contents)Mechanism & Lens motor lock codeDISPLAY CONDITION01 T-REEL LOCK02 S-REEL LOCK03 UNLOADING LOCK04 LOADING LOCK05 CYLINDER51 ZOOMMOTOR LOCK52 FOCUSMOTOR LOCKTurn off the power supply after confirmation,Please do the error cord backup record the clear after repair completion.CLEAR METHODIf the Card and Tape inserted, take out it before Service Mode operation.Making the mode dial of This Machine a pc connection mode push [QUICK START] button and [JOYSTICK LEFT ]button and [RECORDING START/STOP] button simultaneously for 3 seconds.NOTE:1. When an Error Display “PUSH THE RESET SWITCH” on the monitor, it is not necessary to push the MENU button toenter the Service Menu.2. Do not operate items 1 ~ 8 (Except for 3) in the Service Menu.3. To exit the Service Menu, unplug the AC Cord.35NV-GS150E / NV-GS150EG / NV-GS150EB / NV-GS150EP / NV-GS150GC / NV-GS150GN / NV-GS150GCD / NV-GS140E / NV-GS140EG / NV-GS140EB / NV-GS140EP / NV-GS158GK