22Using Web Browser (continued) Mail with the contents shown below is sent when an error has occurred.Command port set up pageSet the port number to be used with command control.Click [Detailed set up] → [Command port set up].1 Input the port number to be used with command control2 Setting update button12=== Panasonic projector report(ERROR) ===Projector Type:PT-EX12KSerial No:12345678----- check system -----MAIN CPU BUS [ OK ]FAN [ FAILED ]FAN(PANEL INTAKE) [ FAILED ]FAN(POWER INTAKE/EXHAUST) [ FAILED ]FAN(MIRROR EXHAUST) [ FAILED ]FAN(LAMP1 INTAKE) [ FAILED ]FAN(LAMP2 INTAKE) [ FAILED ]FAN(PBS INTAKE) [ FAILED ]INTAKE AIR TEMPERATURE [ OK ]OPTICS MODULE TEMPERATURE [ OK ]LAMP1 REMAIN TIME [ OK ]LAMP2 REMAIN TIME [ OK ]LAMP1 STATUS [ OK ]LAMP2 STATUS [ OK ]SHUTTER [ OK ]AIR FILTER [ FAILED ]COVER OPEN [ FAILED ](Error code 40 00 00 22 00 00 0f c0)Intake air temperature :[ 1 degC / 33 degF ]Optics module temperature :[ 10 degC / 50 degF ]PROJECTOR RUNTIME 3 HLAMP1 ECO 400 HLAMP1 NORMAL 401 HLAMP2 ECO 401 HLAMP2 NORMAL 402 HLAMP1 REMAIN 1600 HLAMP2 REMAIN 1600 H-------- Current status --------MAIN VERSION 0.03NETWORK VERSION 0.01LAMP STATUS LAMP1=ONLAMP2=OFFINPUT DVI-DSIGNAL NAME XGA60SIGNAL FREQUENCY 0.00kHz / 0.00Hz----- Wired Network configuration -----DHCP Client OFFIP address 192.168.11.145MAC address 08:00:7b:65:00:11----- Memo -----