51. GENERALThis booklet briefly outlines where and how to install theair conditioning system. Please read over the entire set ofinstructions for the indoor and outdoor units and make sure allaccessory parts listed are with the system before beginning.1-1. Tools Required for Installation (not supplied)1. Flathead screwdriver2. Phillips head screwdriver3. Knife or wire stripper4. Tape measure5. Carpenter’s level6. Sabre saw or keyhole saw7. Hacksaw8. Core bits9. Hammer10. Drill11. Tube cutter12. Tube flaring tool13. Torque wrench14. Adjustable wrench15. Reamer (for deburring)1-2. Accessories Supplied with UnitThe accessory parts are supplied inside the indoor unit.Open the air-intake grille of the indoor unit and take out apackage of accessories.See the section “3-2. Preparation Before Installation”.Table 1-1 (Ceiling)Part Name Figure Q’ty RemarksSpecialwasher 4For temporarilysuspending indoor unitfrom ceilingDrain insulator 2 For drain hose jointFlare insulator1 For gas tube joint1 For liquid tube jointClamper 4 For flare insulatorClamper 1 For wiringDrain hose 1 For main unit + PVC pipejointsHose band 1 For drain hoseconnectionScrew 2 For side cover (L/R)Part Name Figure Q’ty RemarksSide cover (R) 1 (Packed in carton box)For right sideSide cover (L) 1 (Packed in carton box)For left sidePart Name Figure Q’ty RemarksFull-scaleinstallationdiagram1 For positioninginstallationWire cover 1 For control boxScrew 1 For wire coverPart Name Figure Q’ty RemarksOperatingInstructions 1InstallationInstructions 1Warrantycard 1● Use 3/8” (M10) for suspension bolts.● Field supply for suspension bolts and nuts.1-3. Type of Copper Tube and Insulation MaterialIf you wish to purchase these materials separately from a localsource, you will need:1. Deoxidized annealed copper tube for refrigerant tubing.2. Foamed polyethylene insulation for copper tubes as requiredto precise length of tubing. Wall thickness of the insulationshould be not less than 5/16” (8 mm).3. Use insulated copper wire for field wiring. Wire size varieswith the total length of wiring.Refer to “4. ELECTRICAL WIRING” for details.CAUTIONCheck local electrical codes and regulations beforeobtaining wire. Also, check any specified instructions orlimitations.1-4. Additional Materials Required for Installation1. Refrigeration (armored) tape2. Insulated staples or clamps for connecting wire (See yourlocal codes.)3. Putty4. Refrigeration tubing lubricant5. Clamps or saddles to secure refrigerant tubing6. Scale for weighing