4 ENGLISHHOW TO FIX INSTALLATIONPLATE3 INDOOR UNIT INSTALLATION5SELECT THE BEST LOCATION2The mounting wall is strong and solid enough to prevent it fromvibration(Unit in mm)5520075616070Indoor Unitbody≥1556 fromgroundInstallationplate 1Installationplate 4Bolt -size M8WallWall More than 375 More than 375The centre of installation plate should be at more than 375 mm atright and left of the wall.The distance from installation plate edge to ground should morethan 1556 mm.• Always mount the installation plate horizontally plate by aligning themarking thread and using a level gauge.• Mount the installation plate on the wall with 6 sets of plug, bolt andwasher (all non-supply) with size M8.TO DRILL A HOLE IN THEWALL AND INSTALL ASLEEVE OF PIPING41. Insert the piping sleeve to the hole.2. Fix the bushing to the sleeve.3. Cut the sleeve until it extrudes about 15 mm from the wall.CAUTIONWhen the wall is hollow, please be sure to use the sleevefor tube assembly to prevent dangers caused by mice bitingthe connection cable.4. Finish by sealing the sleeve with putty or caulking compound atthe fi nal stage.15 mmPutty or caulking compoundø70 mm through holeIndoor OutdoorSleeve for tubeassemblyApprox. 5 - 7 mmBushing for tube assemblyWallAccess to Internal ComponentsWARNINGThis section is for authorized and licensed electrician/watersystem installer only. Work behind the front plate secured byscrews must only be carried out under supervision of qualifiedcontractor, installation engineer or service person.Please follow the steps below for take out front plate. Beforeremoving the front plate of indoor unit, always switch off all powersupply (i.e. indoor unit power supply, heater power supply and TankUnit power supply).1. Remove the 2 mounting screws which located at bottom of thefront plate.2. Gently pull the lower section of the front plate towards you toremove the front plate from left and right hooks.3. Hold the left edge and right edge of front plate to lift up frontplate from hooks.HookLift upScrews There should not be any heat source or steam near the unit. A place where air circulation in the room is good. A place where drainage can be easily done. A place where noice prevention is taken into consideration. Do not install the unit near the door way. Ensure the spaces indicated by arrows from the wall, ceiling,fence or other obstacles. Recommended installation height for indoor unit shall be at least800 mm. Must install on a vertical wall. When install electrical equipment at wooden building of metallath or wire lath, according to electrical facility technical standard,no electrical contact between equipment and building is allowed.Insulator must be installed in between. Do not install the unit at outdoor. This is designed for indoorinstallation only.100 mmor more100 mmor more100 mmor moreRequired space for installation