6.2. Service Position6.2.1. Extension Cables for Service PositionUsing the following Extension Cables, place the unit as shown for check and service.NO. PART NUMBER PART NAME CONNECTION1 LSUA0017 18Pin Extension Cable FP41 on Main P.C.B. - FP6501 on Front P.C.B.2 VFK1284 24Pin Extension Cable FP62 on Main P.C.B. - Side R F.P.C. of Side R P.C.B.3 VFK1284 24Pin Extension Cable FP81 on Main P.C.B. - LCD Shaft F.P.C. of Side R Unit4 VUVS0012 22Pin Extension Cable LCD Shaft F.P.C. - FP8101 on LCD Backlight P.C.B.5 VFKW0124A 14Pin Extension Cable FP31 on Main P.C.B. - CCD F.P.C. on CCD P.C.B.6 VUVS0012 22Pin Extension Cable FP71 on Main P.C.B. - Lens F.P.C. on Lens Unit7 VUVS0007 12Pin Extension Cable FP72 on Main P.C.B. - OIS F.P.C. on Lens Unit8 VFK1286 16Pin Extension Cable FP61 on Main P.C.B. - Side L F.P.C. on Side L/Ope. Unit9 VFK1286 16Pin Extension Cable FP63 on Main P.C.B. - Top Ope. F.P.C. on Top Ope. UnitNote:1. Use a grounded ESD wrist strap while disassembling the Lens portion.2. Connect the F.P.C.s to the connectors, verifying the direction of F.P.C.s.3. Use extreme care when plugging in or unplugging connectors.20SDR-H18P / SDR-H20P / SDR-H18PC / SDR-H20PC