- 14 -Adjustment Procedure+B Set-Up1. Confirm the main voltage set switchis set to 230V.Note: 230V covers input AC voltage from 200V till 265V, and 110V covers from 90V till 130V.2. Input a Grey scale signal.3. Set the picture controls: -Picture mode NormalWhite balance NormalDriver Set-Up4. Input an APL 100 % white signal.5. Set the picture controls: -Picture mode NormalWhite balance NormalAdjust and confirm indicated test point for the specified voltageTest Point Voltage Volume NameP4 pin 1 (Hot) 400 V ± 1 V R548 PFCConfirmation (Cold)P1 pin 10 15 V ± 0.5 V +15 VP5 pin 1 13 V ± 0.5 V +13 VP6 pin 1 13 V ± 0.5 V Audio 13 VP6 pin 3 -13 V ± 0.5 V Audio -13 VP5 pin 5 5 V ± 0.5 V +5 VP5 pin 8 3.4 V ± 0.5 V +3.3 VP7 pin 1 14 V ± 1 V STB 14VP7 pin 6 5 V ± 0.5 V STB 5 VAdjust driver section voltages referring the panel data on the panel datalabel.Test point Voltage Volume NameTPDA1(C1) 75 V ± 0.5 V R528(P1) VDATPVSUS(SS) VSUS ± 1 V R639(P3) VSUSTPVSET(SC) VSET ± 1 V R6587(SC) VSETTPVSCN(SC) 80 V ± 0.5 V R6597(SC) VSCNTPE(SS) VE ± 0.5 V R494(P1) VEP5 pin3 3 V ± 0.2 V R541 ABL230 V 110 VP6 board