(5) Items of Factory menuWhen in any source, press the “Left -> Exit -> Enter” key of remote control can enter into factory mode.During Factory menu, only “EXIT” key is pushed, system will exit factory mode.Press up and down key can move high light item from Model Change -> Color Temp. Adjust -> Auto GammaAdjust -> Timer Clear -> Preset Channel -> Full Power -> ADC Calibration -> Shipping reset -> Bypass Gamma ->UART Enable -> I2C -> Boot Loader Upgrade -> V-Com Adjust -> SG Pattern.Push “Enter” key can enter high light item function. (Press left and right can adjust value)Display Model version, Release Date, firmware version and released date on the bottom.1)Model IDPress up or down key can select high light item functionPress enter or right key to enter the item.It's only used for FW engineer.2)Color Temp. AdjustPress up or down key can select high light item functionPress enter or right key to enter the item.It's only used for PQ engineer.3)Auto Gamma AdjustPress up or down key can select high light item functionPress enter or right key to enter the item.It's only used for PQ engineer.4)Timer ClearReset the timer which records hours of LED panel burn inThis item will have a check dialog “yes or no” to do or not.- Time in factory mode: Time function shall be displayed automatically. Saving the total time of systempower on (LED turn on), and count the time automatically. The timer is continuous and saved (per 10minutes) forever, unless it will be reset by doing “Timer Clear”.5)Preset channelLoad preset channel for production line.6)Full PowerThis is for power consumption testing.To measure the maximum power consumption of TV set, we adjust the value of following items tomaximum.- Video: Contrast maximum value, Brightness maximum value, Backlight maximum value.- Audio: Volume maximum value, Bass default value, Treble default value.Press enter key to turn on Full Power and OSD stay display until press enter key to recover from FullPower.8