6.25. Remove the K-Board1. Unlock the cable clampers to free the cable.2. Disconnect the coupler (G1). (See section 6.21.)3. Remove the screws (×2 ) and remove the K-Board.6.26. Remove the stand brackets1. Remove the plasma panel section from the servicing standand lay on a fiat surface such as a table (covered) with theplasma panel surface facing downward.2. Remove the stand brackets (left, right) fastening screws (×5each) and remove the stand brackets (left, right).6.27. Remove the Plasma panelsection from the Front frame(glass)1. Remove the front frame and the plasma panel fasteningscrews (×6 ).2. Remove the front frame and the stand brackets fasteningscrews (×4 ).3. For leaving the plasma panel from the front frame, pull thebottom of the front frame forward, lift, and remove.6.28. Replace the plasma panel(finished)1. Place the new plasma panel (finished) on the flat surface ofthe table (covered by a soft cloth), with the plasma panelsurface facing downward.2. Attach the C1-Board and the C2-Board, connect the flexiblecables (×8) from the Plasma panel to the C1-Board and theC2-Board, and fit the flexible cable holders.3. Attach the Hooks (left, right) and fit the stand brackets (L,R) to the new plasma panel.4. Place the plasma panel section on the servicing stand.5. Attach the front frame and each P.C.Board and so on, tothe new plasma panel.* When fitting the front frame, be careful to allow anydebris, dust or handling residue to remain between thefront glass and plasma panel.17TH-37PV60E / TH-37PX60B / TH-42PV60E / TH-42PX60B