242. Remove the cabinet assy and the plasma panel fasteningscrews (×7 ).3. For leaving the plasma panel from the front frame, pull thebottom of the cabinet assy forward, lift, and remove.4. Remove the spacers and spacer rings (×6).5. Remove the BC hook (left, right).Caution:• Please confirm the installation of BC hook (Left, right),Spacer and Spacer Ring when you exchange the PlasmaPanel, and install BC hook (Left, right), Spacer and SpacerRing in an original installation place after exchanging thePlasma Panel.7.21. Replace the plasma panel (fin-ished)1. Place the new plasma panel (finished) on the flat surfaceof the table (covered by a soft cloth), with the plasmapanel surface facing downward.2. Attach the C1-Board and the C2-Board, connect the flexi-ble cables (×16) from the Plasma panel to the C1-Boardand the C2-Board, and fit the flexible cable holders.3. Attach the Hooks (left, right) and fit the stand brackets (L,R) to the new plasma panel.4. Place the plasma panel section on the servicing stand.5. Attach the cabinet assy and each P.C.Board and so on, tothe new plasma panel.*When fitting the cabinet assy, be careful not to allowany debris, dust or handling residue to remainbetween the front glass and plasma panel.