11.5. Sub-Contrast adjustmentName of measuring instrument Connection RemarksRF generatorBase Band generatorPreparation (AV) Remarks1. Receive AV1 (PAL 100% Full White or Split Colour bar shown as below) .2. Goes into service mode, choose Sub-Contrast, and it checks that data value is 512.(It checks that an initial value is a default)Adjustment of AV system Remarks1. The colour key yellow button of remote control is pushed.2. The OSD character of sub-contrast becomes red.(Inside under automatic adjustment)3. The OSD character of sub-contrast returns to white.4. End.Preparation (RF) Remarks1. Receive RF (PAL 100% Full White or Split Colour bar shown as below.)2. Goes into service mode, choose Sub-Contrast, and it checks that data value is 512.(It checks that an initial value is a default)Adjustment of RF system Remarks1. The colour key yellow button of remote control is pushed.2. The OSD character of sub-contrast becomes red.(Inside under automatic adjustment)3. The OSD character of sub-contrast returns to white.4. End.Preparation (HD) Remarks1. Receive Component(1080i/ 60Hz or 1080i/ 50Hz, 100% Full White or Split colour bar as shown below.)2. Goes into service mode, choose Sub-Contrast, and it checks that data value is 384.(It checks that an initial value is a default)Adjustment of HD system Remarks1. The colour key yellow button of remote control is pushed.2. The OSD character of sub-contrast becomes red.(Inside under automatic adjustment)3. The OSD character of sub-contrast returns to white.4. End.39TH-42PV60A / TH-42PV60H / TH-42PV60M / TH-42PV60MT