Panasonic TX-15AT1 Service Manual
Also see for TX-15AT1: Operating instructionsService manual
CONTENTSSAFETY PRECAUTIONS..........................................................................................................................................................2SERVICE HINTS .......................................................................................................................................................................3ALIGNMENT SETTINGS...........................................................................................................................................................4WAVEFORM PATTERN TABLE ...............................................................................................................................................5BLOCK DIAGRAMS ..................................................................................................................................................................6PARTS LOCATION ...................................................................................................................................................................7REPLACEMENT PARTS LIST ..................................................................................................................................................8SCHEMATIC DIAGRAMS .......................................................................................................................................................12CONDUCTOR VIEWS.............................................................................................................................................................17SAFETY PRECAUTIONSGENERAL GUIDE LINES1. It is advisable to insert an isolation transformer in thea.c. supply before servicing a hot chassis.2. When servicing, observe the original lead dress in thehigh voltage circuits. If a short circuit is found, replaceall parts that have been overheated or damaged bythe short circuit.3. After servicing, see that all the protective devicessuch as insulation barriers, insulation papers, shieldsand isolation R-C combinations are correctlyinstalled.4. When the receiver is not being used for a long periodof time, unplug the power cord from the a.c. outlet.5. Potentials as high as 27.5kV are present when thisreceiver is in operation. Operation of the receiverwithout the rear cover involves the danger of a shockhazard from the receiver power supply. Servicingshould not be attempted by anyone who is notfamiliar with the precautions necessary when workingon high voltage equipment. Always discharge theanode of the tube.6. After servicing make the following leakage currentchecks to prevent the customer from being exposedto shock hazard.LEAKAGE CURRENT COLD CHECK1. Unplug the a.c. cord and connect a jumper betweenthe two prongs of the plug.2. Turn on the receiver’s power switch.3. Measure the resistance value with an ohmmeter,between the jumpered a.c. plug and each exposedmetallic cabinet part on the receiver, such as screwheads, aerials, connectors, control shafts etc. Whenthe exposed metallic part has a return path to thechassis, the reading should be between 4M ohm and20M ohm. When the exposed metal does not have areturn path to the chassis, the reading must beinfinite.LEAKAGE CURRENT HOT CHECK1. Plug the a.c. cord directly into the a.c. outlet. Do notuse an isolation transformer for this check.2. Connect a 2kΩ 10W resistor in series with anexposed metallic part on the receiver and an earth,such as a water pipe.3. Use an a.c. voltmeter with high impedance tomeasure the potential across the resistor.4. Check each exposed metallic part and check thevoltage at each point.5. Reverse the a.c. plug at the outlet and repeat each ofthe above measurements.6. The potential at any point should not exceed1,4Vrms. In case a measurement is outside the limitsspecified, there is a possibility of a shock hazard, andthe receiver should be repaired and rechecked beforeit is returned to the customer.X-RADIATION WARNING1. The potential sources of X-Radiation in TV sets arethe high voltage section and the picture tube.2. When using a picture tube test jig for service, ensurethat the jig is capable of handling 27.5kV withoutcausing X-Radiation.NOTE: It is important to use an accurate periodicallycalibrated high voltage meter.1. Set the brightness to minimum.2. Measure the high voltage. The meter should indicate.26.5kV ± 1kV.If the meter indication is out of tolerance, immediateservice and correction is required to prevent thepossibility of premature component failure.3. To prevent any X-Radiation possibility, it is essentialto use the specified tube.HOT CHECK CIRCUITa.c. VOLTMETERWATER PIPE(EARTH)TO INSTRUMENT’S EXPOSEDMETALLIC PARTS Fig. 1.2kΩ 10 Watts2 |
Related manuals for Panasonic TX-15AT1
Panasonic TX-15AT1 Service Manual
Panasonic TX-15M2T Service Manual
Panasonic TX-15PM30T Service Manual
Panasonic TX-15PM10T Service Manual
Panasonic TX-14B3T Service Manual
Panasonic TX-21JT1 Service Manual
Panasonic TC-15LT1 Service Manual
Panasonic TX-14B4T Service Manual
Panasonic TX-14S3TC Service Manual
Panasonic TX-21AT1P Service Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine