Panasonic TX-29PS2D Service Manual
Also see for QuintrixF TX-29PS2D: Operating instructionsService manual
CONTENTSSAFETY PRECAUTIONS ......................................................................................................................................................... 2SERVICE HINTS ...................................................................................................................................................................... 3ADJUSTMENT PROCEDURE AND SELF-CHECK .................................................................................................................. 4WAVEFORM PATTERN TABLE............................................................................................................................................... 5ALIGNMENT SETTINGS .......................................................................................................................................................... 6BLOCK DIAGRAMS.................................................................................................................................................................. 7PARTS LOCATION................................................................................................................................................................. 11REPLACEMENT PARTS LIST................................................................................................................................................ 12SCHEMATIC DIAGRAMS....................................................................................................................................................... 21CONDUCTOR VIEWS ............................................................................................................................................................ 23SAFETY PRECAUTIONGENERAL GUIDE LINES1. It is advisable to insert an isolation transformer in thea.c. supply before servicing a hot chassis.2. When servicing, observe the original lead dress in thehigh voltage circuits. If a short circuit is found, replaceall parts that have been overheated or damaged bythe short circuit.3. After servicing, see that all the protective devicessuch as insulation barriers, insulation papers, shieldsand isolation R-C combinations are correctlyinstalled.4. When the receiver is not being used for a long periodof time, unplug the power cord from the a.c. outlet.5. Potentials as high as 32kV are present when thisreceiver is in operation. Operation of the receiverwithout the rear cover involves the danger of a shockhazard from the receiver power supply. Servicingshould not be attempted by anyone who is notfamiliar with the precautions necessary when workingon high voltage equipment. Always discharge theanode of the tube.6. After servicing make the following leakage currentchecks to prevent the customer from being exposedto shock hazard.LEAKAGE CURRENT COLD CHECK1. Unplug the a.c. cord and connect a jumper betweenthe two prongs of the plug.2. Turn on the receiver’s power switch.3. Measure the resistance value with an ohmmeter,between the jumpered a.c. plug and each exposedmetallic cabinet part on the receiver, such as screwheads, aerials, connectors, control shafts etc. Whenthe exposed metallic part has a return path to thechassis, the reading should be between 4M ohm and20M ohm. When the exposed metal does not have areturn path to the chassis, the reading must beinfinite.LEAKAGE CURRENT HOT CHECK1. Plug the a.c. cord directly into the a.c. outlet. Do notuse an isolation transformer for this check.2. Connect a 2kΩ 10W resistor in series with anexposed metallic part on the receiver and an earth,such as a water pipe.3. Use an a.c. voltmeter with high impedance tomeasure the potential across the resistor.4. Check each exposed metallic part and check thevoltage at each point.5. Reverse the a.c. plug at the outlet and repeat each ofthe previous measurements.6. The potential at any point should not exceed1,4 Vrms. In case a measurement is outside the limitsspecified, there is a possibility of a shock hazard, andthe receiver should be repaired and rechecked beforeit is returned to the customer.X-RADIATION WARNING1. The potential sources of X-Radiation in TV sets arethe high voltage section and the picture tube.2. When using a picture tube test jig for service, ensurethat the jig is capable of handling 32kV withoutcausing X-Radiation.NOTE: It is important to use an accurate periodicallycalibrated high voltage meter.1. Set the brightness to minimum.2. Measure the high voltage. The meter should indicate:31kV ± 1kV.If the meter indication is out of tolerance, immediateservice and correction is required to prevent thepossibility of premature component failure.3. To prevent any X-Radiation possibility, it is essentialto use the specified tube.HOT CHECK CIRCUITa.c. VOLTMETERWATER PIPE(EARTH)TO INSTRUMENT'S EXPOSEDMETALLIC PARTS Fig. 1.2kΩ 10 Watts2 |
Related manuals for Panasonic QuintrixF TX-29PS2D
Panasonic TX-29PS2D Service Manual
Panasonic TX-29PS1P Service Manual
Panasonic TX-29PS12S Service Manual
Panasonic TX-29PS72X Service Manual
Panasonic TX-29PS62Z Service Manual
Panasonic TX-29P82X Service Manual
Panasonic TX-29PM1D Service Manual
Panasonic TX-29PM1D Service Manual
Panasonic TX-29PN1D Service Manual
Panasonic TX-29PN1D Service Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine