268.18. Remove the K-Board1. Remove the Glass holder bottom. (See section 8.17.)2. Remove the claw (×1 ).3. Disconnect the connector (K1) and Remove the K-Boardfrom LED Panel.8.19. Remove the V-Board1. Remove the Glass holder bottom. (See section 8.17.)2. Remove the screw (×1 ).3. Remove the claw (×1 ).4. Disconnect the connector (V14) and remove the V-Boardfrom the 3D emitter panel.8.20. Replace the Plasma panelCaution:A new Plasma panel itself without Hanger metals isfragile.To avoid the damage to new Plasma panel, carry a newPlasma panel taking hold of the Hanger metals afterassembling the Hanger metals and the Stand bracket.1. Place a carton box packed a new Plasma panel on theflat surface of the work bench.2. Open a box and without taking a new Plasma panel;Attach the C1-Board and the C2-Board, connect the flexi-ble cables from the Plasma panel to the C1-Board andthe C2-Board, and fit the Flexible cable holders.3. Attach the Hanger metals and the Stand bracket to thenew Plasma panel.4. Place the Plasma panel on the servicing stand taking holdof the Hanger metals.5. Attach the Cabinet assy and each P.C.Board and so on,to the new Plasma panel.*When fitting the Cabinet assy, be careful not to allow anydebris, dust or handling residue to remain between theFront glass and Plasma panel.