279.15. Remove the C1-Board1. Remove the flexible cables holder fastening screws (×8).2. Disconnect the flexible cables (CB1, CB2, CB3 and CB4).3. Disconnect the flexible cable (C10).4. Remove the screws (×4 ) and remove the C1-Board.9.16. Remove the C2-Board1. Remove the Hanger metal R and the Stand bracket R.(See section 9.14.)2. Remove the flexible cables holder fastening screws (×8).3. Disconnect the flexible cables (CB5, CB6, CB7 and CB8).4. Disconnect the flexible cables (C20, C21 and C26).5. Remove the screws (×4 ) and remove the C2-Board.9.17. Remove the C3-Board1. Remove the Tuner unit. (See section 9.5.)2. Remove the Hanger metal L and the Stand bracket L.(See section 9.14.)3. Remove the flexible cables holder fastening screws (×14).4. Disconnect the flexible cables (CB9, CB10, CB11, CB12,CB13, CB14 and CB15).5. Disconnect the flexible cables (C31 and C36).6. Disconnect the connectors (C33 and C35).7. Remove the screws (×5 ) and remove the C3-Board.9.18. Remove the Plasma panel sec-tion from the Cabinet assy(glass)1. Remove the cabinet assy and the plasma panel fasteningscrews (×3 ).2. For leaving the plasma panel from the front frame, pull thebottom of the cabinet assy forward, lift, and remove.