13The following symptoms do not indicate malfunction.Symptom CauseWater flowing sound during operation. • Refrigerant flow inside the unit.Operation is delayed a few minutesafter restarting.• The delay is a protection for the compressor.Mono bloc unit emits water/steam. • Condensation or evaporation occurring in the pipes.Steam comes out of the mono blocunit in the heating mode.• It is caused by defrost operation in the heat exchanger.Mono bloc unit does not operate. • It is caused by the protection control of the system when outdoor temperature isout of the operating range.System operation switches off. • It is caused by the protection control of the system. When the water inlettemperature is lower than 10 °C, the compressor stops and the backup heaterpower turns on.System is hard to heat up. • When the panel and the floor are heated simultaneously, warm water temperaturemay decrease, which may reduce the heating ability of the system.• When the outdoor air temperature is low, the system may need longer time to heatup.• Discharge outlet or intake inlet in the mono bloc unit is blocked by some obstacle,such as a pile of snow.• When the preset water outlet temperature is low, the system may need longer timeto heat up.System does not heat up instantly. • System will take some time to heat up the water if it starts to operate at cold watertemperature.Backup heater is automatically turnedON when it is disabled.• It is caused by the protection control of the unit heat exchanger.Operation starts automatically when thetimer is not set.• Sterilisation timer has been set.Display power consumption remainsas previous value.• Memory is saved on hourly basis. If a power failure occurs, the data kept from lasthour will be displayed.• Total power consumption has reached 999 days. Press to reset the counter.HEAT indicator blinks on the display. • System is performing deice operation.Loud refrigerant noise continue for afew minutes.• It is caused by protection control during deice operation at outdoor ambienttemperature lower than -10°C.*1 COOL mode is unavailable. • System has locked to operate in HEAT mode only.Check the following before calling for servicing.Symptom CheckOperation in HEAT/ *1 COOL mode isnot working efficiently.• Set the temperature correctly.• Close the panel heater/cooler valve.• Clear any obstruction in the air inlet and air outlet vents of the mono bloc unit.Noisy during operation. • Mono bloc unit has been installed at an incline.• Close the cover properly.System does not work. • Circuit breaker has tripped/activated.Operation LED is not lit or nothing isdisplayed on the remote control.• Check that the power supply is working correctly, or that a power failure has notoccurred.TroubleshootingForce Heater Mode Button• If a malfunction occurs in the system, the backup heater may be used to heat up the water.Press to switch on the backup heater.• Press to switch off the backup heater.• In the Force Heater mode, no other operation can be used.*1 The system is locked to operate without COOL mode. It can be unlocked only by authorised installers or our authorised service partners.*2 Only displayed when COOL mode is unlocked (Means when COOL mode is available).EnglishHow to use / Maintenance / Troubleshooting