3911.4.4 Connect the Cable to the Outdoor Unit(FOR DETAIL REFER TO WIRING DIAGRAM AT UNIT)1 Remove the control board cover from the unit by loosening the screw.2 Connecting cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed (6 × 1.5mm2) flexible cord, type designation 60245 IEC 57 or heavier cord.Outdoor unitTerminals on the indoor unit 1Colour of wiresTerminals on the outdoor unit 1223344553 Secure the cable onto the control board with the holder (clamper).4 Select required direction and apply protective bushing provided in accessories to protect cables from sharpedges.5 Once all wiring work has been completed, tie the cables and cord together with the binding strap so that theydo not touch other parts such as the compressor and bare copper pipes.6 Install back the control board cover.Outdoor UnitBanding strap(Field Supply)Cord clampIndoor/outdoor unitterminal boardConnectingcable (refer belowdiagram for itsguiding)11.4.4.1 Wire Stripping and Connecting Requirement Same as indoor requirement. For details please refer the diagram on AIR-TO-WATER HEATPUMP INDOORUNIT, section 11.3.4 (CONNECT THE CABLE TO THE INDOOR UNIT).Selection ofdirectionProtective bushing 6Apply cutDETAIL OF CONNECTING CABLE GUIDING11.4.4.2 Caution For three phase model never operate the unit by pressing the electromagnetic switch. Never correct the phase by switching over any of the wires inside the unit.11.4.5 Pipe Insulation1 Please carry out insulation at pipe connection portion as mentioned in Indoor/Outdoor Unit InstallationDiagram. Please wrap the insulated piping end to prevent water from going inside the piping.2 If drain hose or connecting piping is in the room (where dew may form), please increase the insulation byusing POLY-E FOAM with thickness 6 mm or above.