41RS485 setup (RS485 SETUP)Refer to the step (7) in 2.5.Data port setup (DATA PORT SETUP)The settings relating to the serial data communication canbe configured on "DATA PORT SETUP" of "COMMUNICA-TION SETUP" on the "WJ-HD88 SETUP MENU".(1) Press the [MENU] button. The "WJ-HD88 SETUP MENU"will be displayed.(2) Move the cursor onto "COMMUNICATION SETUP" andpress the [SET] button.The "COMMUNICATION SETUP" menu will be dis-played.(3) Move the cursor onto "DATA PORT SETUP" and pressthe [SET] button.The "DATA PORT SETUP" menu will be displayed.(4) Configure the following setup items.• "Unit Address (System)"A unit address (System) is a unique number assigningto PS·Data devices. The addresses must be unique toidentify system devices when connecting multipledevices compatible with PS·Data.Numbers, "001"-"099", are to be assigned as the unitaddresses to the system devices.• "Baud Rate"Select the communication speed for data transmissionwith a connected device from the following.2 400/4 800/9 600/19 200/38 400 bps• "Data Bit"It is impossible to change the value for this setting.8 (bit)• "Parity"Select a method to check a transmission error at com-munication from the following."None": No parity check"Even": Even parity"Odd": Odd parity• "Stop Bit"Select a stop bit from the following.1 bit/2 bit• "Retry Timing"Select a retransmission interval for when data receptionis not confirmed from the following.OFF/100 ms/200 ms/400 ms/1 000 ms• "Alarm Data"Select a method to inform the connected controller ofan event occurrence from the following."Off": Does not function."0s": Informs the controller every time an event isdetected."1s/5s": Informs the controller when a specified timehas passed after detecting an event.• "Channel No."It is possible to assign a number to each camera chan-nel to operate cameras using the controller compatiblewith PS·Data.Do the following to assign numbers to the camera chan-nels.(1) Move the cursor onto "Channel No." and press the[SET] button.The "Channel No." menu will be displayed.COMMUNICATION SETUPNETWORK SETUPRS485 SETUPDATA PORT SETUPWJ-HD88 SETUP MENUSYSTEM MANAGEMENTSEARCHREC&EVENT SETUPPTZ SETUPCAMERA SETUPCOMMUNICATION SETUPREPORTUSER INFORMATIONDATA MANAGEMENTDATA PORT SETUP001Unit Address (System)9600Baud Rate8Data BitNoneParity1Stop BitOffRetry Timing1sAlarm DataSetChannel No.OK Cancel