20Camera system setting [SYSTEM SETUP]Performs the settings relating to the camera system such as synchronization, alarm input/output terminal and privacy zone. Thefollowing settings can be configured on the “SYSTEM SETUP” screen displayed from the top screen.Refer to page 5 for how to call up the screen.10. Synchronization method [SYNC]Only internal synchronization (INT) can be used.Multiplexed vertical drive (VD2) synchronization cannot be used.11. Alarm input/output terminal setting [ALARM IN/OUT] CP620 CP600Configure the settings relating to the alarm input/output terminal as follows.Configure the alarm input terminal settingSelect the operation of the alarm input terminal. Follow the procedure below.Step 1“SYSTEM SETUP” screen**SYSTEM SETUP**SYNC INTALARM IN/OUTPRIVACY ZONE OFFSTABILIZER OFFEL-ZOOM OFFUPSIDE-DOWN OFFLDC I...... 0- +RET TOP END“ALARM IN/OUT” screen**ALARM IN/OUT**ALARM IN OFFALARM OUT OFFRET TOP ENDMove the cursor to "ALARM IN/OUT" and press the [SET] button.→ The "ALARM IN/OUT" screen appears.Step 2Move the cursor to "ALARM IN" and select the alarm input terminal operation from the following.OFF (default): No terminal input is accepted.ALARM: Activates the alarm action when the terminal input is active for more than 100 ms.VMD PERMIT: Activates the VMD function when the terminal input is active. It is necessary to set actions to be taken in the "VMD"section in advance.BW: Automatically activates the black-and-white mode when the terminal input is active.SCENE2: Operates the camera with the settings of "SCENE2" when the terminal input is active.When no terminal input is received, the camera will work with the settings of "SCENE1".Note:• The “VMD PERMIT” function is only effective when “VMD” is set to “MOTION DET” or “SCENE CHANGE”.“SYSTEM SETUP” screen**SYSTEM SETUP**SYNC INTPRIVACY ZONE OFFSTABILIZER OFFEL-ZOOM OFFUPSIDE-DOWN OFF- +LDC I...... 0RET TOP ENDALARM IN/OUT