275 ZOOM INVERSEThe TELE/WIDE operation from the lens control terminal or the UP and DOWN buttons isreversed during ON setting.6 FOCUS INVERSEThe FAR/NEAR operation from the lens control terminal or the UP and DOWN buttons isreversed during ON setting.7 REFRESHMove the cursor to REFRESH and press the RIGHT and LEFT buttons at the same timefor more than 2 seconds. Then, the Refresh operation is started.8 CAMERA RESETTING (CAMERA RESET)Move the cursor to CAMERA RESET and press the RIGHT, LEFT, and SET buttons at thesame time for more than 2 seconds.The camera is reset to the factory default settings.Notes:Any of the following cannot be reset to the factory defaults: Preset Position Setting(POSITION SET, PRESET ID, ALC/MANUAL, AF MODE, SCENE FILE),Communication Setting, Password Lock Setting, PIX OFF setting.In case of performing this operation on the condition that the cursor is positioned onother than CAMERA RESET, you cannot perform the operations on the menu thereafter.In that event, set the camera menu to ON again with the controller referring to page 23.Communication SettingMove to the cursor to “COMMUNICTION” and select RS485 or COAX or COAX (RCV).COAX: Communication is carried out in the coaxial multiplex system.COAX (RCV): If our receiver (WV-RC100, WV-RC150, WV-RC170) is used, select COAX (RCV).RS485: Communication is maintained through the RS485 terminal. When RS485 is set upand the SET button is pressed, the RS485 setup screen is displayed.Changing the Camera Communication Parameters for RS485.**COMMUNICATION SETUP**COMMUNICATION RS485RET TOP END** RS485 SET UP **UNIT NUMBERSUB ADDRESSBAUD RATEDATA BITPARITY CHECKSTOP BITXON/XOFFWAIT TIMEALARM DATADELAY TIMERET TOP END1––––192008NONE1NOT USEOFFAUTO2OFF