2. Shoot an object more than 10 meters(30 feet) away to adjust the flange-backof the camera.3. Loosen screws on the flange-backadjusting ring of the camera, then turnthis ring to bring the object into focus.Caution:Do not turn this ring too far counter-clockwise as this could damage theinner glass and CCD image sensor.4. Tighten the screws on the flange-backadjusting ring.5. Set the Zoom Ring to a point between“T” and “W” to choose the desiredangular field of view.6. Bring the desired object into focus byturning the Focus Ring.Note:When shooting an object less than 10meters (30 feet) away, adjust the focusby rotating the flange-back ring of thecamera.SpecificationsImage Size: ø6 mm [4.8(H) x 3.6(V) mm]Focal Length: 3.8 - 8 mmMaximum Aperture Ratio: 1 : 1.4 (Wide) -1 : 1.8 (Tele)Angular Field of View:H: 35.6° - 73.6°V: 26.6° - 53.4°Focusing Range: Adjusted by CameraMount: CS-mount, 1”-32UNAmbient Operating Temperature:–20°C - +60°C (–4°F - 140°F)Dimensions: ø40 x 49.3 mm (ø1-9/16” x1-15/16”)Weight: 53 g (0.12 lbs.)Dimensions and weight indicated areapproximate.Specifications are subject to changewithout notice.Panasonic Security and Digital Imaging CompanyA Division of Matsushita Electric Corporation of AmericaExecutive Office: One Panasonic Way 3E-7, Secaucus, New Jersey07094Regional Offices:Northeast: One Panasonic Way, Secaucus, NJ 07094 (201) 348-7303Southern: 1225 Northbrook Parkway, Suite 1-160, Suwanee, GA30024 (770) 338-6838Midwest: 1707 North Randall Road, Elgin, IL 60123 (847) 468-5211Western: 6550 Katella Ave., Cypress, CA 90630 (714) 373-7840Panasonic Canada Inc.5770 Ambler Drive, Mississauga,Ontario, L4W 2T3 Canada (905)624-5010Panasonic Sales CompanyDivision of Matsushita Electric of Puerto Rico Inc.Ave. 65 de Infanteria. Km. 9.5San Gabriel Industrial Park, Carolina,Puerto Rico 00985 (809)750-4300N0100-0 YWV8QA5435AN Printed in JapanN 19