7112.11 nanoe-G Operation This operation provides clean air by producing great amount of negative ions and distribute through thedischarge airflow to capture or deactivate molds, bacteria or viruses. nanoe-G operation start conditiono During unit running at any operation mode, if nanoe-G operation is activated, combination operation(operation mode + nanoe-G operation) starts.o During unit is OFF, if nanoe-G operation is activated, nanoe-G individual operation starts. nanoe-G operation stop conditiono When OFF/ON button is pressed to stop the operation.o When nanoe-G button is pressed.o When OFF Timer activates. nanoe-G operation pause conditiono When indoor fan stop (during deice, odor cut control, thermostat off, etc.). nanoe-G operation resume afterindoor fan restarts.o When indoor intake temperature ≥ 40°C. nanoe-G operation resume after indoor intake temperature ≤ 40°Ccontinuously for 30 minutes. Indoor fan controlo During any operation mode combines with nanoe-G operation, fan speed follows respective operation mode.However, nanoe-G system enabled when fan speed ≥ 500rpm to ensure proper negative ion distribution,nanoe-G system disabled when fan speed < 500 rpm.o During nanoe-G individual operation, only Auto Fan Speed and no Powerful operation is allowed. Even if FanSpeed button is pressed, no signal is sent to the unit and no change on remote control display. Auto FanSpeed for nanoe-G operation changes from SHi to Hi after 4 hours of operation. Airflow direction controlo During any operation mode combines with nanoe-G operation, airflow direction follows respective operationmode.o During nanoe-G individual operation, only Auto Air Swing is allowed. Even if Air Swing button is pressed, nosignal is sent to the unit and no change on remote control display. Timer controlo When ON Timer activates when unit stops, previous operation resumes and restored last saved nanoe-Goperation status.o When ON Timer activates during any operation, no change on current operation.o When OFF Timer activates during any operation, all operation stops and the latest nanoe-G operation statusis saved. Indicatoro When nanoe-G starts, nanoe-G indicator ON. Remote control receiving soundo Normal operation nanoe-G operation : Beepo Nanoe-G operation Normal operation : Beepo Stop nanoe-G individual operation : Beepo Nanoe-G individual operation Stop : Long Beep Power failureo During nanoe-G individual operation, if power failure occurs, after power resumes, nanoe-G individualoperation resumes immediately.o During combination operation, if power failure occurs, after power resumes, combination operation resumeimmediately.