5Connecting the COM Port to an Asynchronous TerminalA VT100-compatible asynchronous terminal or a PC providing VT100 terminalemulation must be used to set up access to and management of the unit.Procedure1. Configure the terminal or PC to be compatible with the FrameSaver unit:— COM Port in use by your PC: COM1 or COM2.— COM Port Baud Rate set to 19.2 Kbps.— Character length set to 8 data bits.— Parity set to none.— Stop bit set to 1.— Flow Control set to None.2. Insert the DB25 end of the EIA-232 cable into the FrameSaver unit’s COM port.3. Insert the other end of the cable into the terminal or PC.4. Tighten the screws on each side of the connector to secure them.5. Press Enter on the keyboard to display the Main Menu.If the Main Menu does not appear, recheck the terminal or PC settings (see Step 1),or press the Enter key. Refer toTroubleshooting in theFrameSaver SLV OperationsGuide for other possible explanations.Verifying that Self-Test PassedTo verify that the unit passed its self-test, go to the System and Test Status screen.Main Menu→Status→System and Test StatusThe results of the self-test appears directly under the screen title.If any failure messages appear, reset the unit by disconnecting, then reconnecting thepower cord. The unit will perform the self-test again. If the failure reappears, call yourservice representative for assistance.POWERCOMDBMMDMNETTo Connect to a PCor Async TerminalCOMPort99-16348