Customizing DSX-1-Compatible Units4-57914-A2-GB20-00 February 1998Configuring Framed or Unframed Operation(DSX-1-to-DSX-1 Configuration)In Switchpack Mode, specify Unframed operation by setting switches 3 – 7 onswitchpack S4 to OFF.Configuring a Starting Time Slot (DSX-1-to-V.35/V.11 Configuration)In Switchpack Mode, switches 3 – 7 on switchpack S4 determine the starting timeslot, as shown in Table C-1 on page C-2.If the payload rate (configured on the V.35/V.11-compatible unit) is 1544 kbps, setswitches 3 – 7 all to the OFF position. This is the factory default.If the payload rate isless than 1544 kbps, use switches 3 – 7 to select a startingtime slot (DS0). Make sure that there are enough subsequent time slots toaccommodate the V.35/V.11 payload rate (refer to the Maximum Payload Ratecolumn in Table C-1 on page C-2). Contact your network administrator to verifyyour starting time slot selection, as some time slots may already be in use.Displaying Switchpack DefinitionsTo display the definition of each position in switchpack S4, enter 5 at the Configprompt. Switchpack definitions are also listed in Appendix C,SwitchpackDefinitions.Config→ 4Switch pack S4 definitions:1 – CO/CP OFF=CP, ON=CO2 – AMI/B8ZS OFF=AMI, ON=B8ZS3–7 – Starting Time Slot (CO only) 1–24 = Starting Time Slot25-30 = Starting Time Slot = 2431 = Switchpack Disable8 – D4/ESF OFF=D4, ON=ESFSwitch pack S5 definitions:1–3 – LBO see table below4–8 – N/A< a key to continue!>>Possible values for each parameter are listed in Table 4-1. See Appendix A,Worksheets, for help in selecting the appropriate configuration options for yourapplication. PreviousNext |