13Configuration SetupThe Console connection is optional, used to locally configure the router. Refer to Step 5on page 9 ofInstalling the Hotwire 6341/6342 SDSL Router for details.The Console cable is connected to a VT100-compatible terminal or a PC running aterminal emulation program. Verify the terminal settings: Data rate is set to 19.2 kbps (19200 bps). Character length is set to 8. Parity is set to None. Stop bits is set to 1. Flow control is set to Off or None.Accessing the RouterWhen the local console connection is first established, access control to the SDSLrouter displays an initial prompt of Login>.Procedure1. At the initial prompt of Login>, enter the factory default Login ID of paradyne.2. At the password> prompt, enter the factory default Password of abc123.3. At the next prompt for System ID, the factory default is CUSTOMER>.Type show system to display hardware/firmware information and Selftest Results(optional).Refer to theHotwire DSL Routers User’s Guide for configuration settings and commandline entries.LED Symptom ActionPWR LED is off. Check that the power cord is securely installed on bothends.If no LEDs are on, the power supply may be defective.Test the outlet to verify power.If other LEDs are on, the PWR LED may be burned out.Unplug the unit and reapply power; watch all LEDs duringthe power-on self-test to verify that the PWR LED isfunctioning. If the problem persists, contact the serviceprovider.TST LED is on. A test initiated by the service provider may be active. Waitten minutes. If the TST LED does not go off, contact theservice provider.