11-3 Technical Specifications512C Series ConverterElectrical RatingsINPUT RATINGS SYMBOL 512C/04 512C/08 512C/16 512C/32Supply Voltage Vs 110/120220/240 Vac ± 10%380/415460/480 (1)Supply Current Is 6A 12A 24A 48ASupply Frequency fs 50/60 Hz ± 5 HzOUTPUT RATINGSNominal ArmatureVoltageVa 90 Vdc at 110/120 Vac180 Vdc at 220/240 Vac320 Vdc at 380/415 VacMaximum ArmatureCurrentIa 4A dc ±10% 8A dc ±10% 16A dc ±10% 32A dc ±10%Armature CurrentCalibrationIcal 0.5 to 4Ain 0.5A steps1 to 8Ain 1A steps2 to 16Ain 2A steps4 to 32Ain 4A stepsNominal Motor Power at320 Vdc Armature PmHp1.125kW1 1/ 2 Hp2.25 kW3 Hp4.5 kW6 Hp9 kW12 HpOverload 150% for 60 secondsField Current If 3 A dcField Voltage Vf 0.9 X Supply Voltage (Vs)Maximum Armature FormFactor 1.5Thyristor I2t 300 A2sTypical ControllerDissipation at Ia 15W (2) 25W (2) 50W (2) 75W (2)Earth Leakage Without Filter - 5mA (3)Current at 480Vac With Filter - 50mANote:1. 460/480 Vac Operation is available when used with an auxiliary supply input of asuitable standard value.2. See page 3-2 for filter watt loss information.3. Permanent earthing mandatory.www.comoso.com