32 Description2.1 Technical SpecificationFlow DataStated flows are for operation at 7 bar g (100 psi g / 0.7 MPa g) with reference to 20ºC, 1 bar a, 0% relative water vapour pressure.PerformanceISO 8573-1 classifications apply when the dryer is installed with the filtration suppliedReference conditions: 20o C, 1 bar(a), dry. Compressed air conditions: 7 bar overpressure, 35o COperating DataElectrical DataModel Pipe SizeInlet OutletL/s m3 /min m 3/hr cfm L/s m3 /min m 3/hr cfmBAM10 G 2 113 6.8 408 240 90.4 5.4 326.4 192BAM20 G 2 170 10.2 612 360 136 8.2 489.6 288BAM30 G 2 213 12.8 765 450 170.4 10.2 612 360BAM40 G 2 283 17.0 1020 600 226.4 13.6 816 480BAM50 G 21/2 354 21 1275 750 283.2 16.8 1020 600BAM70 G 21/2 496 30 1785 1050 396.8 24 1428 840Dryer ModelPressure Dewpoint(Standard)ISO 8573-1:2010Water Classificationo C o F (Standard)All Models -40 -40 Class 2Contaminants Units Inlet Challenge(All Models)Outlet Levels(All Models)EuropeanPharmacopoeiaOil / Lubricant mg/m 3 Ref. 11.3 0.011 0.1Water ppm 7,913 24 67Carbon Monoxide (CO) ppm 39 <0.01 5Carbon Dioxide (CO 2) ppm 744 109 500Oxygen (O 2 ) Vol.-% 20.9 20.9 20.4 - 21.4Nitrogen Oxides (NO + NO2 ) ppm 13 1.8 2Sulphur Dioxide (SO 2) ppm 7 <0.01 1ModelMin Operating Pressure Max OperatingPressureMin OperatingTemperatureMax OperatingTemperaturebar g psi g bar g psi g o C o F o C o FAll Models 4 58 13 188.5 5 41 35 95BAM10 BAM20 BAM30 BAM40 BAM50 BAM70Supply Voltage 90 - 264V 1PH 50/60HzConnection Type Hard wiredPower 21 W (Max)Fuse 11 Fuses are Anti surge (T) 250VAC, 5x20mm, HBC, Breaking capacity 1500A @250VAC, IEC 60127-2, UL/CSA Ceramic body.T3.15A