22IQAN-XS2 Technical OverviewAppendix AInstruction book, IQAN-XS2Appendix AIQAN-XS2 Technical OverviewAbsolute Maximum Ratingsaa. The “Absolute Maximum Ratings” table lists the maximum limits to which the device can be subjectedwithout damage. This doesn´t imply that the device will function at these extreme conditions, onlythat, when these conditions are removed and the device operated within the “Recommended OperatingConditions”, it will still be functional and its useful life won’t have been shortened.Parameter RemarkAmbient temperature, TAStorage temperature-40 °C to +85 °C-40 °C to +100 °CVoltage supply on +BAT 6 - 34 VVoltage on any pin with respect to -BAT 34 V with external 20 A fuse(for reverse polarity protection)Maximum current into -VREF 2 AMaximum current sourced by all outputs <20 AEnvironmental ratingsParameter RemarkEMIISO 14982:1998, Radiated emissionEN 55025:2003, Conducted emissionISO 11452-2:1995, Radiated SusceptilbilityISO 11452-4:2001, Conducted SusceptibilityISO 7637-2:2004, Conducted transient susceptibility on powerISO 7637-3:1995, Conducted transient susceptibility on signal30-1000 MHz0.15-108 MHz, class 120-1000 MHz, 100V/m1-200 MHz, 150mA1,2a,2b,3a,3b,4, 580VESDISO 10605:2001, ESD 15KV, air,8 KV contact4 KV handlingMechanical environmentIEC 60068-2-64:1993 Fh, Random vibrationIEC 60068-2-29:1987 Eb, Bump0.4 g²/Hz, 15- 250 Hz, 10 hours40g, 6 ms,1000 in each directionClimate environmentIEC 60529:2001, Enclosure protectionDIN 40050 Part 9:1993, Enclosure protectionIEC 60068-2-30:1985 Db, Damp heat cyclicIEC 60068-2-78:2001, Damp heat, steady stateIEC 60068-2-14:1984 Nb, Change of temperatureIP66: 100 l/min, 3minIP6K9K: 1000kPa, +80°C, 30sec55°C, 6 cycles40°C, 93% RH, 21 days-40°C to 70°C, 100 cyclesChemical environmentIEC 60068-2-52:1996 Kb, Salt mist 3 days