MX80S Series Product Manual7 Parker Hannifin CorporationEMN Automation - ParkerIrwin, PennsylvaniaSpecification ConditionsSpecifications Are Temperature DependentCatalog specifications are obtained and measured at 20 Degrees C. Specifications at any othertemperature may deviate from catalog specifications. Minimum to maximum continuous operatingtemperature range (with NO guarantee of any specification except motion) of a standard unit beforefailure is 5 - 40 degrees C.Specifications Are Mounting Surface DependentCatalog specifications are obtained and measured when the positioner is fully supported, bolteddown, and is mounted to a work surface that has a maximum flatness error of:0.001mm/300mm (0.00004”/ft)Table will operate with work surface of 0.100mm/300mm flatness or worse, but performance speci-fications will be significantly effected.Specifications Are Point of Measurement DependentCatalog specifications and specifications in this manual are measured from the center of the car-riage, 38 mm above the carriage surface. All measurements taken at any other location may devi-ate from these values.Specifications Are Load Mounting DependentCatalog specifications are obtained and measured when the customer load is fixed to the carriagemounting surface(s) and has a flatness of equal to or less than 0.0025mm (0.0001”). The table willoperate with customer load surface greater than 0.0025mm (0.0001”) flatness, but performancespecifications will be significantly effected.