11www.parker.com/euro_pneumatic10. Shut Down and Storage• Turn the air supply to “OFF”.• Disconnect the air motor from the air supply.• Disconnect the air motor from the equipment it is attached to.• Remove the silencer package (if one is installed).• Blow clean and dry air (using a low pressure) into the air-inletport of the air motor.• Drip a couple of oil-drops into the inlet port and turn the shaftby hand to distribute the oil. Recommended oil:see chapter 7 – “Lubricants”.• Close all connections.• The air motor may now be stored until needed again.11. Technical DataThe air motors are supplied as “Components for installation” – theinstaller is responsible for ensuring that the motors are installed safelyin the overall system.Parker Pneumatic guarantees that its products are safe, and as asupplier of pneumatic equipment we ensure that the equipment isdesigned and manufactured in accordance with the applicable EUdirective.Most of our products are classed as components as defined by variousdirectives, and although we guarantee that the components satisfy thefundamental safety requirements of the directives to the extent that theyare our responsibility, they do not usually carry the CE mark.Nevertheless, most P1V-S motors carry the CE mark because they areATEX certified (for use in explosive atmospheres).The following are the currently applicable directives:• Machinery Directive(essential health and safety requirements relatingto the design and structure of machines and safety components)• EMC Directive• Simple Pressure Vessels Directive• Low Voltage Directive• ATEX Directive (ATEX = ATmosphere EXplosive)12. CE markingEC-Declaration of Incorporation in accordance with theEC Machinery Directive 2006/42/EC, Annex IIBAs supplier of the partly completed machine we declare that:• the essential requirements of the Directive 2006/42/EC and whereapplicable the other Directives and Standards listed below apply tothe specified machine.• the relevant technical documentation is compiled in accordance withpart B of Annex VII.• the relevant technical documentation in accordance with part B ofAnnex VII will be transmitted in response to a reasonable request bythe national authorities in printed form or in electronic form (pdf).Required documents have been filed - under Directive 2014/34/EU,Annex VIII - with the following authority:IBExU, Institut für Sicherheitstechnik GmbH EU reference numberIBExU15ATEXB006 X.Supplier Parker Hannifin ManufacturingGermany GmbH & Co. KGPneumatic Division EuropeIndustriestrasse 870794 Filderstadt Germany13. EC-Declaration of IncorporationPlease refer to the technical catalogue PDE2554TC