12 VMM2404InputsFor an input that is active-high It must be connected to battery power so that there is a battery connectionwhen the state of the input changes. The power provided to the digital switch connected to the input must beprovided through a fuse in the wire harness.A typical active-high digital input connection is shown below:Internal to productActive HighDigital InputBatteryApplication SwitchFigure 3: Active high digital input3.1.2. Multi-Purpose Used as Analog InputAnalog inputs are typically used to read electrical signals that span a voltagerange.The following multi-purpose inputs can be used as analog inputs: INPUT1_ADF to INPUT15_ADF