17Battery does not appear to accept chargewhen battery is plugged into the charger.Charger gets hot, makes excessively loudnoise, or smokes during charging cycle.Charger cord or wall plug gets hot.Inoperative indicator lights on charger, ordefective charger.Battery damaged or cycle life exhausted.Damaged charger.Try battery in tool after a full charge cycle.If tools indicator light is red, charger notworking properly. Replace charger, ormonitor charging time to ensure battery hasadequate time for recharging. It is normalfor battery to feel warm after properlycharging.Replace battery.Discontinue use immediately and unplugfrom power source. Replace charger andtag or dispose of charger to preventaccidental re-use or connection to powersource.Preparing Tool for Operation - Battery/Charger ProblemsECIVRESSMELBORPELBISSOPMOTPMYSNormal Stage of OperationFan does not run - tool indicator light isblinking red or solid red.Fan does not run, or runs slower thannormal - tool indicator light is solid red.Battery is not charged.Battery terminals are oily, dirty, or corroded.Battery is discharged.Charge battery.Clean battery terminals with soft cloth.Charge battery.ECIVRESSMELBORPELBISSOPMOTPMYSWork-contacting element does not depressfully - tool does not operate.Tool will not cycle - fan runs, indicator lightis solid green.Work-contacting element is bent, or build-up ofdebris in track restricts operation.Lockout feature is engaged.Fuel Cell empty.Spark wire out of spark plug.Spark plug is dirty.No spark is generated.Remove and inspect lower probe. Clean thetrack. Repair or replace lower probe asrequired.Add strip of nails.Replace fuel cell.Remove cap and check spark lead, insert inspark plug and replace cover.Clean tool cylinder head.Return tool to authorized Paslode ® dealer forservice.Troubleshooting