PHI 5000 04 DIAGNOSTIC MODE10/8ERRORCODES DESCRIPTION01 The coffee grinder is blocked02 The grinder is disconnected03 The brewing unit is blocked in work position04 The brewing unit is blocked in home position05 The hydraulic circuit is clogged10 The temperature sensor is in short circuit11 The temperature sensor is opened14 The temperature was up to 170°15 The machine doesn’t heat up19 The net is not stable22 The keyboard is not recognized4.4. Error codesLastErrorLogged 0 Last error saved in machineGr_bu_uc_arr[jj] 150 Array of last 4 brew unit effort during rinsing cycle (inmilliamperes). Autozero for new autodose systemGr_time_aroma[Light] 3000 Grinding time for aroma 1 (ms)Gr_time_aroma[Medium] 3500 Grinding time for aroma 2 e aroma 3 (ms)Gr_time_aroma[Strong] 4000 Grinding time for aroma 4 e aroma 5 (ms)Coffe_Duct_empty TRUE Set grinder conduct clean – used to increasegrinding time for first grinding product nextpower-on.DebugGrinder FALSE If true machine enter in debug mode nextpower-on.Filter_autonomy 0 Autonomy of last Aqua clean filter activedFilter_counter 0 Number of Aqua clean filter actived in aquacleanchainFilter_startup_qty 5000 Counter of water for enable first Aqua Cleanfilter; if expire, the machine need a descalingaction to activate a new filter.InstallFilterRemind TRUE Request Aqua clean filter activation next poweronFilterPulses 0 Impulses brew through Brita filter (not used in IncantoMachine)