FACTORY ADJUSTED METHOD VER1.03-11. Color temperature adjustmentPush the factory service key to into the adjustment mode. The picture will appear asfollowDVI 7180ºkX=308 Y=298GAIN BiasRGB RGBXXX XXXUse the AV key to select the color to adjust andorkey to adjust the level.The required equipments are CA-100,Vp300.a. Adjust Bias first to let the Y be 0.4 on CA-100. Adjust R or B to let the valueof X,Y on CA-100 be the same as the value showing screen, The value of Yshould be Maintained 0.55 during the adjusting.b. Move the cursor to adjust Gain. The value of Y should be adjusted to 35.Then adjust R or B to let the value of X,Y on CA-100 be the same as thevalue showing on screen. The value of Y should be maintain 20 during theadjustment.c. Repeat to check the Bias and Gain. The value of Y,X and Y should be thesame as the previous adjusted value. Then the DVI 7180ºk mode is adjustedcompletely.d. Push the factory service key again to next picture. Then repeat the steps a.b. c. to adjust.e. If the adjustment is completed, repeat d. a. b. and c steps to adjust again.f. When the last mode AV 10180ºk is adjusted completely, push the factoryservice key again to leave the adjustment mode,Note: 1. There are 9 adjusted modes(DVIx3.RGBx3 Avx3)2. The adjusted sequence is DVI´RGB´AV.3. DVI: Bias Y=0.55Gain Y=36RGB: Bias Y=0.70Gain Y=36YPbPr : Bias Y=1.2Gain Y=41