46 ENGLISHMachine actions Causes SolutionsThe machine grinds thecoffee beans but no coffeecomes out.(See note)There is no water. Fill the water tank and prime thecircuit (see the "Using the Machinefor the First Time" chapter).The brew group is dirty. Clean the brew group (see the"Weekly Cleaning of the BrewGroup" chapter).The circuit is not primed. Prime the circuit (see the "Using theMachine for the First Time" chapter).This might occur when the ma-chine is automatically adjustingthe dose.Brew a few cups of coffee asdescribed in the “Saeco AdaptingSystem” chapter.The dispensing spout is dirty. Clean the dispensing spout.Coffee is too weak.(See note)This might occur when the ma-chine is automatically adjustingthe dose.Brew a few cups of coffee asdescribed in the “Saeco AdaptingSystem” chapter.Coffee is brewed slowly.(See note)The coffee grind is too fine. Change coffee blend or adjust thegrind as explained in chapter "Ad-justing the Ceramic Coffee Grinder".The circuit is not primed. Prime the circuit (see the "Using theMachine for the First Time" chapter).The brew group is dirty. Clean the brew group (see the"Weekly Cleaning of the BrewGroup" chapter).Coffee leaks out of the dis-pensing spout.The dispensing spout is clogged. Clean the dispensing spout and itsholes.Note:These problems can be considered normal if the coffee blend has beenchanged or if the machine has just been installed. In this case wait until themachine performs a self-adjusting operation as described in the "SaecoAdapting System" chapter.