10HD7806/50 /51 /52 /59Adjusting the scale factor for the strong/short(60 ml) cup volume.13. Remove the water tank from the machine. (foradjusting the right parameter, the internal SWwill check if the water level sensor is activatedyes/no)14. Press the 1- and 2 cup button simultaneouslyand plug the mains on.15. Release the 1- and 2 cup button, if successful,the on/off LED will switch on less bright/intense as normal, indicating the scale factorreprogramming has entered.16. Depending if the volume has to de- or increaseyou have to push the one- or two-cup button.Every time you push the 1- or 2-cup button,the LED will turn off for 0.5 second (feedbackto user) and the scale factor will be shortenedor lengthened depending which button waspushed.Pushing 1-cup button, scale factor will beshorten approximately - 1 cc/ml (less coffee)Pushing 2-cup button, scale factor will belengthen approximately + 1 cc/mL (morecoffee)The new value will be stored when you switchthe appliance off by pushing the main switch.(LED will turn off)17. Turn appliance on again and brew one strongcoffee cup by pressing the 1-cup button twice,measure the volume. In case the volume is notwithin specification repeat steps 13 – 17.18. EndExample table, switching from WEU to French/Spain specification or vice versa, you need toexecute below:Restoring the Boiler_empty flag to productiondefault:Sometimes it is needed, that the boiler of theSENSEO have to be emptied.This for instance in wintertime were the possibilityexists that the boiler becomes frozen duringtransport e.g.For those occasions, it is handy to restore theBoiler_empty_flag again to production default.Bringing the SENSEO back into production status,has the benefit the flush routine will be activatedautomatically when installed by the consumer, seetopic Automatic filling procedure.How to SET the Boiler_empty_flag:Keep the 1-cup button pressed while pluggingin the power plug of the appliance in the mainssocket.The main switch LED will blink very rapidly forapproximately 1 second.To check if the Boiler_empty_flag is really set,reconnect the power plug to the mains a secondtime and push the main switch. The main switchLED should light continuously.Change volume setting Adjusting normal/smooth 1-cup volumestep 6- 12Adjusting short/strong 1-cup volumestep 13 - 17WEU => French/Spain Push 7x 1-cups with water in tank 16x 2cups without tankFrench/Spain => WEU Push 7x 2-cups with water in tank 16x 1cups without tankFunctions/features explanation