2–Event MessagesInformative Events2-72 59060-07 DInformative EventsInformative events are events that occur in the normal activities of a fabric. Thefollowing lists the event ID and text of the message along with an explanation ofthe message.(I) (8200.0001) (mserver) (Hotreset is not permitted at this time, try again later)Meaning: The switch was busy at the time of the attempted hot reset. Try thehot reset again later.(I) (8200.0002) (mserver) (Port: port_number) (Rejecting request from address FC_address,inband management is disabled on port port_number)Meaning: A Management Server command was received on a port that isconfigured to refuse inband management requests.(I) (8200.0100) (mserver) (Cannot map number_of_characters characters to SwitchSymbolic Name (max number_of_characters))Meaning: The RIELN management server command was processed, and theInterconnect Element Logical Name was registered. However, theregistered name is of greater length than the maximum lengthallowed for the Switch Symbolic Name, so therefore the SwitchSymbolic Name was not changed to match the registered name.(I) (8200.0101) (mserver) (Cannot map non-printable characters to Switch Symbolic Name)Meaning: The RIELN management server command was processed, and theInterconnect Element Logical Name was registered. However, theregistered name contains unprintable characters. These charactersare not allowed for the switch symbolic name, therefore the switchsymbolic name was not changed to match the registered name.(I) (8200.0200) (mserver) (Rejecting request (GZM) for zone zone_name containingunsupported alias member(s)Meaning: The fabric zone server command GZM (Get Zone Member) wasrejected because the requested zone member was an alias that isnot defined in Fibre Channel General Services-3 (FC-GS-3).(I) (8200.0201) (mserver) (Rejecting request command:command)Meaning: A fabric zone server command was rejected for the reason detailedin the message. This can be caused by two users attempting toconfigure the switch or zoning database at the same time. Contactyour authorized maintenance provider if the reason for the failure isnot clear.