August 3, 2015 7044-225D 1931-I ACCFigure 19.2Figure 19.3Figure 19.4Cast Iron Flue Located on ApplianceDrill through all 8 countersunklocationsOnce distance is established, drill holesand secure both chambers together.Figure 19.5C. Securing Stove Pipe/Liner to Flue Collar1. There are 4 pre-drilled holes in the flue collar 90 degreesapart. Attach the flue collar to the stove pipe/liner. If theseal is questionable use high temperature sealant suchas stove mastic Figure 19.1.2. Attach gasket to bottom side of flue collar with a thin coatof silicone.Flue Collar Stove Pipe/LinerGasketFigure 19.1D. Optional Offset Adapter InstallationIn some installations the flue collar and stove pipe/liner donot always align properly. This situation may be remediedby using the optional offset adapter. See Appliance Dimen-sions page for the amount of distance this accessory cantelescope between the flue collar and stove pipe/liner.1. Remove the cast iron flue collar from the appliance andflip it upside down. Using the larger #7 drill bit supplied,drill through all 8 countersunk locations. Figure 19.2.2. Slide the gasket over the flue collar and attach it to theoffset adapter using the 8-32 flathead screws provided.Figure 19.3.3. Adjust the offset adapter to desired distance. Drill holesthrough the lower chamber as shown in Figure 19.4using the small drill bit #26 provided.4. Cut the gasket to the proper length and slide in betweenthe upper and lower chambers centered on the screwholes. Attach the upper and lower chambers with screwsprovided. Figure 19.5.5. Repeat the process on the bottom side.