13Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/063 Installing the FireplaceStep 1. Locating the FireplaceThe diagram below shows space and clearance require-ments for locating a fireplace within a room.Figure 4A. Fireplace Dimensions and LocationsClearance RequirementsThe top, back, and sides of the fireplace are defined bystand-offs. The minimum clearance to a perpendicular wallextending past the face of the fireplace is one inch (25 mm).The metal ends of the fireplace may NOT be recessed intocombustible construction.Note: Refer to Figure 4B for dimensions and appliancelocations if installing a QV-PIER-HV unit with a Catalinashelf and/or marble package.Note: Refer to the Catalina installation instructionincluded with kit for assembly and installation. Figure 4B.50-1/2 in. 34-1/2 in.7 in.47-1/2 in.45-1/4 in.13/16 in.Marble sizes (inches):Header .................................. 26 x 8Side headers .................. 45-1/2 x 8Legs ................................ 33-1/2 x 7Í45 -1/4 in.(1149mm)FINISHEDWALLFireplace Locations/Dimensions withCatalina Shelf/Marble Package ONLYÎÎNote: This location diagram MUST be followed when in-stalling a QV-Pier-HV with a Catalina shelf/marble packagesince the fireplace is installed further from finished wall.36"GLASSGLASS36"GLASSGLASSGLASS36"36"36"QV-PIER-HV-IPITOP VIEWQV-ST-HV-IPITOP VIEW