9Quadra-Fire • QFI30FB, QFI35FB • 2221-900 Rev. K • 3/11G. IPI Battery Tray/Battery InstallationThe IntelliFire Plus TM system has a battery backup option.Battery longevity and performance will be affected by theservice temperatures of this appliance.NOTICE: Batteries should only be used as a power sourcein the event of an emergency such as an outage.The removable battery tray is located in the lower leftcorner of the appliance next to the lower glass clip. Removebatteries from tray before sliding tray back into appliance.See Figure 2.3.A notch on the right side of the tray engages the tray with theappliance. See Figure 2.4. To remove the tray, rotate theleft side of the tray outward and pull to the left to disengagethe notch. Place the batteries in the tray and return it to theclosed position with the notch engaged in the appliance.Figure 2.3 Location of Battery TrayFigure 2.4 Pull Left Side of Tray Out and Disengage NotchFigure 2.5 Battery Tray Pulled OutNOTCHH. Control Module Operation1. The control module has an ON/OFF/REMOTE selectorswitch that must be set. See Figure 2.6.OFF Position: Appliance will ignore all power inputs andwill not respond to any commands from a wall switch orremote. The unit should be in the OFF position duringinstallation, service, battery installation, fuel conversion,and in the event that the control goes into LOCK-OUTmode as a result of an error code.ON Position: Appliance will ignite and run continuouslyin the HI flame setting, with no adjustment in flameoutput. This mode of operation is primarily used forinitial installation or power outage operation with batterybackup.REMOTE Position: Appliance will initiate commandsfrom an optional wired wall switch and/or the wirelessremote (RC300).2. If using a wired wall switch with the module in REMOTEmode, the flame output can be adjusted with the HI/LOselector switch on the module. See Figure 2.6. Notethat the flame HI/LO selector switch will become inactiveonce an optional remote control (RC200/RC300) isprogrammed to the control module. Note that the controlmodule will always ignite the fireplace on HI and remainso for the initial 10 seconds of operation. If the HI/LOis switched to the LO position, the flame output willautomatically drop to the lowest setting after the flamehas been established for 10 sec. After this 10 secondperiod, the flame can be adjusted from HI to LO withthe switch.3. The control module has safety feature that automaticallyshuts down the fireplace after 9 hours of continuousoperation without receiving a command from the RC300remote.4. If you intend to use both an optional wired wall switchand the RC300 remote control to operate your fireplace,the wall switch will override any commands given bythe remote.Figure 2.6 Control ModuleNG/LP SETTINGSTATUS INDICATOR LEDSELECTORSWITCHFLAME HI/LO SWITCH