August 3, 2015 7075-209E 11VOYAGEUR GRANDRecommendedLocationMarginalLocationLocationNotRecommendedRecommendedLocationLocation NOTRecommendedMulti-level RoofsWindwardLeewardOutside Air Kit Termination CapFigure 11.1D. Chimney Termination RequirementsFollow manufacturer’s instructions for clearance, securingflashing and terminating the chimney.• Must have an approved and Listed cap• Must not be located where it will become plugged bysnow or other material• Must terminate at least 3 feet (91cm) above the roofand at least 2 feet (61cm) above any portion of theroof within 10 feet (305cm).• Must be located away from trees or other structuresC. Locating Your Stove & ChimneyLocation of the appliance and chimney will affect perfor-mance. As shown in Figure 11.1 the chimney should:• Install through the warm space enclosed by the build-ing envelope. This helps to produce more draft, espe-cially during lighting and die down of the fire.• Penetrate the highest part of the roof. This minimizesthe affects of wind turbulence and down drafts.• Consider the appliance location in order to avoid floorand ceiling attic joists and rafters.• Locate termination cap away from trees, adjacentstructures, uneven roof lines and other obstructions.Your local dealer is the expert in your geographic area andcan usually make suggestions or discover solutions that willeasily correct your flue problem.NOTICE:• Chimney performance may vary.• Trees, buildings, roof lines and wind conditions affectperformance.• Chimney height may need adjustment if smoking oroverdraft occurs.NOTICE: Locating the appliance in a basement or in alocation of considerable air movement can cause intermittentsmoke spillage from appliance. Do not locate appliance near• Frequently open doors• Central heat outlets or returns