5:6 2005-09Trouble shootingfelsökning cdc.inddTrouble shooting Electrodrive CDCFor installation and operation, see Operator’s Manual 12155016.Symptom A ON/OFF lamp does not give light when P0 is activated1. Press P4 and / or P5a. If L1 and/or L2 gives light, exchange lamp in P0b. If L1 and/or L2 doesn’t give light, check power source including fuses. See Wiringdiagram in Operator’s manual 12155016.2. Check L10 and L11a. If L10 and L11 doesn’t give light, connect connector C1 directly to C2. If then L10 andL11 gives light, exchange CANBUS cable.b. Disconnect seven-pole connector for loaderc. If L10 and L11 doesn’t give light, exchange control box. If that doesn’t help, see d.d. If L10 and L11 doesn’t give light, exchange joystick.Symptom B No function for boom and bucket1. Factory settinga. Restore factory setting. See Manual 12155016.2.Check error codes on control box and joysticka. Check the reason for error code in error code list. Code 3+4 deactivated by pressing P5. SeeManual 12155016.b. Connect ground cable between bracket for Joystick and chassis. See manual 12155016.3. Check signal transmissiona. When manoeuvring the joystick in X- and Y- direction, L12, L13, L14 and L15 shall givelight for each respective direction. L16 is always giving light 30sec after start and 4sec aftermanoeuvring.4. Check CANBUS-cablea. Connect connector C1 to C25. Check connector C3a. Cleanseb. Check connector pins in connector6. Check servo pressurea. Increase to 2000 rpmb. Measure servo pressure in M (BSP 1/4”). Use equipment withstanding 0-210bar.c. Override proportional pressure reducing valve ”C” (only for open centre) accordingto”Symptom B”, 7a.d. Check spool for servo pressure generating (only open centre)7. Check proportional pressure reducing valvesa. Override proportional pressure reducing valves. Solenoids are activated mechanically inhole Ø 2mm close to the connector. See manual 12155016.b. Proportional pressure reducing valves are interchangeable8. Check system pressurea. Measure pressure in port P