30INSPECTING THE VENTINGAn inspection of both the inner and outer vent pipes and the vent terminal should be made as part of the annualservice appointment. The venting must have no blockage and be in good repair. The vent manufacturer’sinstructions may provide specific details on vent inspection. Any vent sections that are disassembled must bereassembled and sealed as required.CLEANING THE LOGS, BURNER AND FIREBOXDuring the annual inspection and maintenance appointment, the service person should clean the logs, burner andfirebox. To gain access to the firebox, logs and burner, follow the instructions beginning on page 15 of this manual.An extra-soft brush should be used to gently clean the logs and burner as they are extremely fragile. DO NOT USEA VACUUM CLEANER TO CLEAN THE LOGS OR BURNER.A vacuum cleaner may be used to clean the metal parts of the firebox. Replace the logs and embers after cleaning.Follow the instructions on pages 18-21 of this manual to insure proper placement of the logs and ember chunk onthe burner.AIR FLOWThe VIVA L utilizes a convection air heat exchange system to maximize heat delivered from the stove. It isimportant that air flows freely through the convection air system and out the front and side air grills. Do not placeobjects under the stove that will block the convection air inlet flow or in front of any air outlet.MAINTENANCE LOGThis appliance should be inspected before use and at least annually by a qualified service person. Morefrequent cleaning may be required due to excessive dust or lint from carpeting, bedding materials, pets, etc.It is imperative that control compartments and circulating air passageways of this appliance be kept clean.28PARTS LIST.To be inserted here.