9Accessing Stored MeasurementsThe meter has the capability of storing up to 64 values during a singlemeasuring period. In order to recall these values, follow the steps below:1. Press the MEM button four times and hold it down.2. The meter will begin to countdown from 20 to 1 RPM indicating it iscompiling the stored values.3. Once the countdown is completed, a total of the values storedwill display as "An XX", whereas XX will be the number of storedmeasurements.4. Press the MEM button repeatedly to scroll through each stored value.Battery Replacement1. When the bottom left corner of the LCD displays the batteriesshould be replaced.2. Open the Battery Cover located on the back of meter and removethe batteries.3. Replace with 4 new AA batteries, check that the polarization iscorrect and reinstall the cover.Accessories and Replacement PartsST-TIPL Large Cone AdapterST-TIP Cone AdapterST-FUNNEL Funnel AdapterST-SHAFT Shaft Extension AdapterST-WHEEL Surface Wheel AdapterRT100 Reflective Tape for TachometersCA-05A Soft Carrying CaseDon't see your part listed here? For a complete list of all accessories andreplacement parts visit your product page on www.reedinstruments.com.1.888.610.7664info@REED-Direct.com REED-Direct.com