REGULATION INSTRUCTIONS315. REGULATING THE APPLIANCE5.1 Parameters tableNOTES:P04 – This parameter allows adjustment of the time taken to reach the maximum heating load. (Heating curve).P10, P11, P12 – These parameters are automatically adjusted according to the value set in parameter P00.P13 –Range rating of maximum heating load according to the graph “Heating power (Kw) – Fan frequency (Hz)” on Page39.P15 - If the heating system has more than one zone, an additional interface board (optional extra) can be installed on thecircuit board and parameter 15 set at 01.P16 - To install the telephone control, use non-polarised conductors connected to contact TA of the terminal board inparallel with the remote control if fitted. Set the parameter 16 at 01.PARAMETER N° TYPE OF OPERATION PARAMETER VALUE FUNC TIONP00 Selects the model of boiler0001(default)02030400 = 24Kw01 = 28Kw02 = 29Kw03 = 34 Kw04 = 50 KwP01 Selects the type of boiler00010200 = Instantaneous01 = Boiler with storage tank02 = B. w/storage tank Comfort (+7°C)P02 Selects the type of gas 000100 = Natural gas01 = LpgP03 Sets the central heatingtemperature000100 = Standard (30-80°C)01 = Reduced (25-40°C )P04 Heating output rising time0001(default)02030400 = 0sec01 = 50 sec02=100 sec03=200 sec04=400 secP05 Water hammer preventionfunction000100 = Off01 = OnP06 D.H.W priority function 000100 = Off01 = OnP07 Central heating timer 00-90 (default = 36)Delays the heating restart to preventfrequent On/Offs, Expressed in steps of 5sec (factory set at 36 x 5 = 180”)P08 Central heating pump overruntimer 00-90 (default = 36)The overrun timer can be modified.Expressed in steps of 5 sec (factory setat 36 x 5 = 180”)P09 D.H.W pump overrun timer 00-90 (default = 18)The overrun timer can be modified.Expressed in steps of 5 sec (factory setat 18 x 5 = 90”)P10 Minimum fan speed setting Preset To set the minimum frequency value (Hz)for the fan operationP11 Maximum fan speed setting Preset To set the maximum frequency value(Hz) for the fan operationP12 Minimum fan speed setting(Central Heating) Preset To set the minimum frequency value (Hz)for the fan operation in heating modeP13 Maximum fan speed setting(Central Heating) AdjustableTo set the maximum frequency value(Hz) for the fan operation in heatingmodeP14 Ignition sequence setting 33-203 To set the fan frequency value (Hz) at theignitionP15 Zone management boardactivation000100 = Off01 = OnP16 Telephone control activation 000100 = Off01 = OnP17 Fan frequency value display 000100 = Off01 = On