8lb NOTE: This appliance is not intended for useby persons (including children) with reducedphysical, sensory or mental capabilities, or lackof experience and knowledge, unless theyhave been given supervision or instructionconcerning use of the appliance by a personresponsible for their safety.Children should be supervised to ensure thatthey do not play with the appliance.lc WARNING: If the supply cord of an outdoorcontroller is damaged, it must be replaced bya special cord or assembly available from themanufacturer or its service agent.If the supply cord of an indoor controlleris damaged, it must be replaced by themanufacturer, its service agent or similarlyqualified persons in order to avoid a hazard.Wiring ConnectionsConnect the valve wires for each Zone and for(optional) Master Valve, Pump Start Relay or RainSensor.lb NOTE: If installing an outdoor model, routeall field wires through conduit or through theknock-out on back of the unit.Connect Zone ValvesConnect the power wire from each Zone valveto the corresponding Zone number on thecontroller terminal block.Connect the common wire from each valve tothe COMMON (C) terminal.ZONE 1VALVEPOWERCOMMONZONE 2VALVEETC.ESP-RZZONEOFF AUTOT2W3TH4F5S6SU7M1DATE/TIMESCHEDULEMANUALSEASONALADJUSTBACK OFF ON NEXTREMOTE24VACACCESSORYSENS 1 2 3 4 5 6 7 8C MRESETConnect Master ValveConnect an optional Master Valve to the ESP-RZcontroller.Connect the power wire from the master valveto the master (M) terminal on the controllerterminal block.Connect the common wire from the mastervalve to the COMMON (C) terminal.COMMONMASTERVALVEPOWERESP-RZZONEOFF AUTOT2W3TH4F5S6SU7M1DATE/TIMESCHEDULEMANUALSEASONALADJUSTBACK OFF ON NEXTREMOTE24VACACCESSORYSENS 1 2 3 4 5 6 7 8C MRESET